Compressor Room Design Checklist (Tropical Edition)

Most compressor-room problems in tropical plants come from heat and humidity: machines that derate or trip, dryers that can't keep up and condensate that ends up in the air main. Check these points at design stage and at every expansion.

Layout and access

  • Clearances to the manufacturer's minimums on every side, plus room for service
  • Lifting route and door size for the largest component
  • Space reserved for the next compressor and dryer
  • Floor drainage and bunding where oil is present

Ventilation and heat

  • Heat load calculated from the installed kW of compressors and dryers
  • Cooling air drawn from the coolest, cleanest side of the building
  • Hot discharge air ducted out, with no recirculation to intakes
  • Fan capacity checked at the highest expected ambient temperature
  • Heat-recovery opportunity assessed before the duct is designed

Treatment and condensate

  • Dryers sized for the worst-case inlet temperature, pressure and ambient
  • Filters matched to the ISO 8573-1 class each user needs
  • Zero-loss or level-controlled drains on every separation point
  • Condensate routed to an oil-water separator, not the storm drain

Electrical and controls

  • Supply capacity and protection for start-up current
  • Metering for kW and kWh on the hall
  • Sequencer or master controller considered for multi-compressor rooms
  • Space and network for monitoring and alarms
Nexus Turnkey · +855 14 706 062 · nexusengimpexp@gmail.comGeneral guidance. Apply with qualified engineering judgement.