Capture the solvent, protect the finish, keep the permit

VOC control for printing and coating plants means capturing solvent-laden air at the press, booth or oven and treating it with the right technology for its volume and concentration: activated carbon, a zeolite rotor concentrator, or a regenerative thermal oxidiser. Nexus Turnkey sizes the extraction and treatment together, then supplies the clean, dry, oil-free compressed air that spray finishes need and the filtration that keeps booths clean. We design to the limit in your environmental permit.

Printed sheets running through the rollers of a printing press
Factory cross-section highlighting the air services used in Printing & coating: Emissions control, Compressed air, Air treatment, Dehumidification, HVAC & chillers, Monitoring (AirSight). PRODUCTION HALLN₂+
Fig. · Factory cross-section, air services

Printing & coating

VOC control for printing and coating

In printing and coating, the air leaving the plant matters as much as the air going in. The lens shows solvent capture at presses, booths and ovens, VOC treatment matched to volume and concentration, dry and oil-free spray air, filtered booth supply air and humidity control for stable substrates.

Air services in focus: Emissions control, Compressed air, Air treatment, Dehumidification, HVAC & chillers, Monitoring (AirSight).

Explore printing & coating

The challenge

Flexographic and gravure printing, laminating, coil and wood coating, and spray painting all release solvent vapour. Odour reaches neighbours, VOCs breach permits, and workers breathe what capture misses. Treatment is expensive to run if the airflow is oversized, and the wrong technology for the load wastes energy or fails its limit. Inside the booth, oil or water in spray air ruins finishes. Paper and board change dimension as humidity swings, which upsets registration.

The air services a printing or coating plant needs

VOC treatment starts with capture: hoods, enclosures and duct velocities sized so solvent is collected at source. Treatment is then matched to the stream. Options are activated carbon for small or intermittent loads, a zeolite rotor concentrator for large dilute flows, and an RTO for continuous, higher concentrations. Our comparison of activated carbon, zeolite rotor and RTO sets out the trade-offs. See air quality and emissions.

Booths need paint-stop, ceiling and supply filters from filters and media, classified under ISO 16890.

Spray air needs a dryer, coalescing filters and carbon filtration at the gun. See air treatment.

Dehumidifiers hold paper and board stores and press halls at a steady relative humidity.

TVOC sensors at the stack and in the workplace show treatment is working. See air quality and emissions solutions.

What we check first

VOC projects go wrong when treatment is sized before anyone measures the exhaust. We start with the following.

  • Capture at source. Smoke tests and face-velocity readings at hoods and booths show what is captured and what escapes into the hall.
  • A solvent balance. The solvent your plant buys each month, less what leaves in product and waste, sets an upper bound on what the exhaust can contain. It is a useful check on any measured concentration.
  • Concentration and hours. Treatment choice depends on how concentrated the stream is and how many hours it runs. Ducts carrying solvent vapour are kept well below the lower explosive limit, with monitoring where concentrations are high.
  • Spray-air quality at the gun. A dew-point and oil check at the booth often explains finish defects that were blamed on paint.

This turns a vague odour or permit problem into a sized, costed design.

Standards and limits

Typical scope

PackageWhat it usually includes
SurveyExhaust volumes, solvent load, operating hours, capture review
TreatmentCarbon, zeolite rotor or RTO, fans, stack, controls
BoothsSupply and exhaust filtration, spray-air treatment
Climate and monitoringDehumidification, TVOC and differential-pressure monitoring

Start with design and engineering, or read the industrial air quality guide.

Scope

Relevant standards

Standards that commonly shape this industry's air
StandardWhy it matters here
ISO 8573-1:2010Purity classes for compressed air. Oil and water in spray air cause finish defects, so the class is set at the gun.
ISO 16890Classifies supply-air filters for booths and clean finishing rooms.
Environmental permit limitsVOC and odour limits come from your permit. We design treatment to meet them and provide the design basis.
We design to the standard your process requires. Nexus describes these standards; it does not claim certification against them.

FAQ

Questions engineers ask us

Activated carbon, zeolite rotor or RTO: which suits us?

Carbon suits low volumes or low, intermittent loads. A zeolite rotor concentrates large, dilute airflows so a small oxidiser can destroy the solvent. An RTO suits higher concentrations and continuous operation, recovering heat to keep running costs down. Volume, concentration, solvent type and operating hours decide.

Why do we get craters and fisheyes in the finish?

Oil or water in spray air is a common cause, along with contaminated substrates. A dryer, coalescing and carbon filtration at the booth and a written ISO 8573-1 class for spray air remove the air-side cause.

Can we reduce the airflow we have to treat?

Often. Tighter capture hoods, enclosed presses and recirculation where safe can reduce the exhaust volume, and a smaller airflow is cheaper to treat. We survey capture first.

Next step

Size VOC treatment to your real exhaust

Tell us your solvents, exhaust volumes and hours. We will recommend the capture and treatment that fits your permit.