A
- Activated carbon
- A highly porous carbon that adsorbs vapours and odours, used in compressed air filters to remove oil vapour and in ventilation and exhaust systems to remove VOCs and odour.
- Aftercooler
- A heat exchanger that cools hot compressed air leaving the compressor so that most of its water vapour condenses and can be separated and drained before the dryer.
- AHU (air handling unit)
- A packaged unit of fans, filters, coils and dampers that conditions and moves air for a building or process space through ductwork.
- Air receiver
- A pressure vessel that stores compressed air to buffer demand peaks, stabilise system pressure and reduce compressor cycling.
- AMC (annual maintenance contract)
- A contract under which a service provider maintains equipment over a year or longer for an agreed scope, typically covering preventive maintenance, parts and response to breakdowns.
B
- Baghouse
- A dust collector that filters dusty air through rows of fabric bags, cleaned periodically by pulses of compressed air or by shaking or reverse air.
- Base load
- The steady, minimum air demand a plant draws through a production period, normally carried by fixed-speed compressors running fully loaded.
C
- cfm (cubic feet per minute)
- An imperial unit of volumetric flow, widely used for compressor capacity; 1 m³/min equals about 35.31 cfm.
- Chiller
- A refrigeration machine that cools water or a water-glycol mixture, which is then pumped to air handling units, process equipment or heat exchangers.
- CMH (cubic metres per hour)
- Cubic metres per hour (m³/h), the usual unit for airflow through fans, air handling units, filters, dehumidifiers and emissions control systems.
- Coalescing filter
- A compressed air filter that captures oil and water aerosols by merging fine droplets into larger ones that drain away, along with fine particles.
- Condensate
- The liquid water, usually mixed with oil and dirt, that drops out of compressed air as it is cooled after compression.
- Cooling tower
- A heat rejection unit that cools water by evaporating a small part of it into an airstream, used with water-cooled chillers, compressors and process equipment.
- COP (coefficient of performance)
- The ratio of useful cooling or heating output to electrical power input for a chiller, heat pump or air conditioner, expressed as a dimensionless number.
- Cyclone separator
- A dust separator with no moving parts that spins the airstream in a conical body so that centrifugal force throws particles to the wall and down into a hopper.
D
- Desiccant dryer
- A compressed air dryer that removes water vapour by adsorption onto a desiccant bed, reaching pressure dew points of -40 °C or -70 °C.
- Desiccant rotor
- A slowly rotating wheel impregnated with desiccant that dries air passing through one sector while a heated airstream regenerates another, used in desiccant dehumidifiers.
- Dew point
- The temperature to which air must be cooled, at constant pressure and moisture content, for its water vapour to start condensing.
- Dust collector
- An extraction and filtration system that captures airborne dust at the source and separates it from the conveying air, using cartridges, filter bags or cyclones.
E
- EER (energy efficiency ratio)
- A cooling efficiency ratio of cooling output to power input at stated rating conditions, given in Btu/h per watt in US practice or as a kW/kW ratio in European standards.
- EN 779
- The former European standard for general-ventilation filter classes (G1-G4, M5-M6, F7-F9), superseded by ISO 16890.
- ePM1
- A filter's efficiency against particles of 0.3 to 1 µm under ISO 16890; an 'ISO ePM1' filter captures at least 50% of them.
F
- FAD (free air delivery)
- The volume of air a complete compressor package actually delivers, measured at its outlet and expressed at the conditions of the air drawn in at its inlet.
- FAT (factory acceptance test)
- Testing equipment at the supplier's works before shipment to confirm it is built and performs as specified, witnessed or reviewed by the buyer.
H
- Heat recovery (compressors)
- Capturing the heat a compressor rejects -- from its oil cooler or cooling air -- and using it for process water, boiler feed or space heating instead of dumping it.
- HEPA filter
- A high-efficiency particulate air filter classified under EN 1822-1 or ISO 29463, with H13 and H14 grades capturing at least 99.95% and 99.995% of particles at the most penetrating particle size.
I
- IE motor class
- The international efficiency class of an electric motor under IEC 60034-30-1, from IE1 (standard) to IE4 (super premium), with IE5 (ultra premium) defined in later standards.
- ISO 11011
- The international standard that sets out how to carry out and report an energy-efficiency assessment of a compressed air system.
- ISO 14644
- The international series of standards for cleanrooms and controlled environments; Part 1 classifies air cleanliness by airborne particle concentration, from ISO Class 1 to ISO Class 9.
- ISO 16890
- The international test and classification standard for general-ventilation air filters, which rates filters by their efficiency against PM1, PM2.5 and PM10 particles.
- ISO 8573-1
- The international standard that defines compressed air purity classes for particles, water and oil, written as a three-figure class such as [1:4:1].
K
- kWh/m³ (specific energy)
- The electrical energy a compressed air system uses per cubic metre of air delivered, measured over time at plant level.
L
- Laminar flow (unidirectional airflow)
- Filtered air moving in parallel streams at uniform velocity across a work zone, sweeping particles away before they settle on product or surfaces.
- Leak rate
- The share of a compressed air system's output lost through leaks, usually expressed as a percentage of compressor capacity or as a flow when production is stopped.
- Load/unload control
- A fixed-speed compressor control method that runs the motor continuously and switches the airend between full output and zero output to hold pressure within a band.
M
- Membrane separation (nitrogen)
- A nitrogen generation method that passes compressed air through bundles of hollow polymer fibres, letting oxygen, water vapour and CO₂ permeate out faster than nitrogen.
N
- N+1 redundancy
- A design rule that installs one more unit than needed to meet peak demand, so any single machine can fail or be serviced without losing supply.
- Nm³ (normal cubic metre)
- A cubic metre of gas expressed at stated 'normal' reference conditions of temperature and pressure, so quantities measured under different conditions can be compared.
O
- Oil-free compressor
- A compressor whose compression chamber contains no oil, so no lubricant is introduced into the air it delivers.
- Oil-injected screw compressor
- A rotary screw compressor that injects oil into the compression chamber to seal the rotors, absorb heat and lubricate, then separates it from the air before discharge.
- Oil-water separator
- A unit that separates oil from compressor condensate so the water can be discharged and the oil collected for proper disposal.
P
- P&ID (piping and instrumentation diagram)
- A schematic drawing that shows the process equipment, piping, valves, instruments and control loops of a system and how they connect.
- Packed-bed scrubber
- A wet scrubber in which exhaust gas flows through a column of packing media wetted by a scrubbing liquid, giving a large contact area to absorb soluble gases and odours.
- Pass box
- A small chamber with two interlocked doors set into a cleanroom wall, used to transfer materials between areas of different cleanliness without opening a direct air path.
- PLC (programmable logic controller)
- A rugged industrial computer that reads inputs, runs control logic in real time and drives outputs for machines and systems.
- PM-VSD (permanent-magnet variable speed drive)
- A variable-speed compressor drive that uses a permanent-magnet synchronous motor instead of an induction motor, keeping motor efficiency high across a wide speed range.
- PM2.5
- Airborne particulate matter with an aerodynamic diameter of 2.5 micrometres or less, fine enough to penetrate deep into the lungs.
- Positive pressure (room)
- Keeping a room at a slightly higher air pressure than its surroundings by supplying more filtered air than is extracted, so air leaks outwards and contaminants stay out.
- Pressure dew point (PDP)
- The temperature at which water vapour in compressed air starts to condense, measured at the air's actual line pressure.
- PSA (pressure swing adsorption)
- A gas separation process that produces nitrogen from compressed air by adsorbing oxygen onto carbon molecular sieve under pressure and releasing it when the pressure is lowered.
- ΔP (pressure drop)
- The loss of pressure as air flows through pipes, filters, dryers, hoses and fittings, between the compressor and the point of use.
R
- Refrigerated dryer
- A compressed air dryer that chills the air with a refrigeration circuit to condense and remove water, typically to a pressure dew point of around +3 °C.
- Relative humidity (RH)
- The amount of water vapour in air as a percentage of the maximum it could hold at the same temperature.
- Ring main
- A compressed air distribution header laid as a closed loop, so air reaches each take-off from two directions with lower pressure loss.
- Roots blower
- A rotary lobe blower in which two counter-rotating lobed rotors move pockets of air from inlet to outlet without internal compression, supplying low-pressure air or vacuum.
- Rotary screw compressor
- A positive-displacement compressor in which two meshing helical rotors trap air and reduce its volume continuously as they turn.
- RTO (regenerative thermal oxidiser)
- An emissions control system that destroys VOCs by oxidising them at high temperature, recovering most of the heat in ceramic media beds to keep fuel use low.
S
- SAT (site acceptance test)
- Testing installed equipment and systems on site, under real operating conditions, to confirm they meet the specification before handover.
- SCADA (supervisory control and data acquisition)
- A software system that collects data from plant equipment and controllers, displays it centrally, logs history and raises alarms, with limited supervisory control.
- Sequencer
- A master controller that decides which compressors run, load and stand by in a multi-compressor system, to hold one pressure band with the fewest machines.
- Side-channel blower
- A regenerative blower in which an impeller repeatedly accelerates air through a side channel, building moderate pressure or vacuum at relatively low flow.
- Specific power
- The electrical power a compressor package draws per unit of free air delivered, usually stated in kW per m³/min or kW per 100 cfm at a stated pressure.
T
- Trim compressor
- The compressor in a multi-machine system that follows changes in demand, while base-load machines run fully loaded.
- Turbo blower
- A high-speed centrifugal blower, usually direct-driven by a permanent magnet motor on magnetic or air-foil bearings, delivering oil-free low-pressure air.
- TVOC (total volatile organic compounds)
- A single figure summarising the combined concentration of volatile organic compounds in air, whose value depends on the measurement method and calibration used.
- Two-stage compression
- Compressing air in two stages in series, with an intercooler between them, so each stage works over a smaller pressure ratio and less energy is lost as heat.
U
- Ultrasonic leak detection
- Locating compressed air and gas leaks by detecting the high-frequency sound produced by turbulent flow through the leak, using a handheld or acoustic-imaging instrument.
- Unloaded power
- The electrical power a fixed-speed compressor still draws while running unloaded, delivering no compressed air.
V
- Venturi scrubber
- A wet scrubber that accelerates exhaust gas through a narrow throat where it atomises the scrubbing liquid, capturing fine particles, mists and fumes in the droplets.
- VSD (variable speed drive)
- An electronic drive that varies a compressor motor's speed so air output follows demand instead of switching between full load and unload.
W
- Wet scrubber
- An air pollution control device that removes gases, odours, mists or particles from an exhaust stream by bringing it into contact with a scrubbing liquid.
Z
- Zeolite rotor concentrator
- A slowly rotating honeycomb wheel of hydrophobic zeolite that adsorbs VOCs from a large, dilute exhaust stream and releases them into a much smaller, hotter airstream for destruction.
- Zero-loss drain
- An automatic condensate drain that senses the liquid level and opens only to discharge water, without venting compressed air.
Next step
A term we haven't defined?
Ask us. If it matters to your plant, it probably belongs here.