What the converter does
Compressor and dryer datasheets mix units: cfm and m³/min, psig and bar g, hp and kW. Quotations from two suppliers can look different when they are the same machine, or the same when they are not. This converter handles the arithmetic and, more importantly, flags the cases where a unit conversion is not enough.
It covers four quantities:
| Quantity | Units |
|---|---|
| Flow | cfm, m³/min, m³/h, L/s |
| Pressure | bar, psi, kPa, MPa (gauge and absolute) |
| Power | kW, hp |
| Temperature | °C, °F, K |
Every factor comes from exact definitions listed in NIST Special Publication 811: the foot is exactly 0.3048 m, the bar exactly 100 kPa, and the pound-force and horsepower are defined exactly from those. We carry full precision and round only for display.
How to use it
- Choose the quantity: flow, pressure, power or temperature.
- Type the value and pick the unit it is in. Every other unit updates as you type.
- For pressure, say whether your value is gauge or absolute. The default atmosphere is the standard 101.325 kPa; enter your local barometric reading for site work.
- Share the link to send the same conversion to someone else.
How to read the results
Flow: same unit, different air
A cubic metre is only comparable with another cubic metre at the same reference conditions:
- FAD (free air delivery) is compressor output measured to ISO 1217 and stated at inlet conditions. It is what compressor datasheets quote.
- Normal cubic metres are corrected to a reference temperature and pressure, commonly 0 °C and 1.01325 bar absolute, dry. Nitrogen and gas flows are often stated this way.
- ISO 8573-1 states purity per cubic metre at 20 °C, 100 kPa absolute and zero humidity.
- scfm has several definitions in use.
The converter changes units, not reference conditions. Correcting between them needs temperature, pressure and humidity, which is engineering work, not a factor. For more on cfm and m³/h, see the glossary.
Pressure: gauge or absolute
Plant gauges read pressure above atmosphere (bar g, psig). Absolute pressure adds the atmosphere, about 1.013 bar at sea level. Compression ratios, gas laws and dew-point calculations need absolute values.
Dew point
Pressure dew point is the temperature at which water condenses at line pressure, and it is the figure ISO 8573-1 water classes 1—6 use. Atmospheric dew point is always lower for the same air, so the two must never be compared directly. The US DOE / CAC sourcebook quotes refrigerant-type dryers at 35—39 °F (about 2—4 °C) pressure dew point and twin-tower desiccant dryers typically at −40 °F (−40 °C).
Limits you should know
- Conversions are exact to the digits shown. What a number means depends on the datasheet you took it from.
- Horsepower here is mechanical horsepower. Electrical input power is higher than shaft power by the motor losses.
- Temperature differences convert differently from temperatures: a 10 K difference is 18 °F, not 50 °F.
When to call an engineer
If you are comparing compressor quotations, sizing a nitrogen generator from a gas flow in Nm³/h, or checking a dryer against a dew-point requirement, the reference conditions matter more than the units. Our design and engineering team can put competing offers on the same basis, and an air audit measures flow and dew point on your system. See also how to choose an air compressor and the compressed air guide.