Toolkit · ISO 8573-1 class explorer

Write the air quality you need as three numbers your supplier can't misread

ISO 8573-1:2010 specifies compressed air purity as three classes, written particles:water:oil, for example ISO 8573-1:2010 [2:4:2]. Particle classes 1–5 cap particle counts per cubic metre in three size bands; water classes 1–6 cap the pressure dew point (class 4 is +3 °C or lower); oil classes 1–4 cap total oil, including vapour, from 0.01 to 5 mg/m³. Class 0 is a limit agreed between user and supplier that is stricter than class 1, not zero contamination. This explorer lets you pick each class, shows the notation in plain English and the treatment typically needed, as a direction to confirm with your process owner.

Pick one class for each contaminant

Solid particles (first digit)
Maximum number of particles per m³ by particle size d, or mass concentration Cp (ISO 8573-1:2010 Table 1)
Class0.1 < d ≤ 0.5 µm0.5 < d ≤ 1.0 µm1.0 < d ≤ 5.0 µm
As specified by the equipment user or supplier and more stringent than class 1
≤ 20,000≤ 400≤ 10
≤ 400,000≤ 6,000≤ 100
Not specified≤ 90,000≤ 1,000
Not specifiedNot specified≤ 10,000
Not specifiedNot specified≤ 100,000
Mass concentration: 0 < Cp ≤ 5 mg/m³
Mass concentration: 5 < Cp ≤ 10 mg/m³
Mass concentration: Cp > 10 mg/m³
Water (second digit)
Pressure dew point (classes 1–6) or liquid water concentration Cw (classes 7–9, X) (ISO 8573-1:2010 Table 2)
ClassLimit
As specified by the equipment user or supplier and more stringent than class 1
PDP ≤ −70 °C
PDP ≤ −40 °C
PDP ≤ −20 °C
PDP ≤ +3 °C
PDP ≤ +7 °C
PDP ≤ +10 °C
Liquid water Cw ≤ 0.5 g/m³
0.5 < Cw ≤ 5 g/m³
5 < Cw ≤ 10 g/m³
Cw > 10 g/m³
Oil (third digit)
Total oil concentration: aerosol, liquid and vapour (ISO 8573-1:2010 Table 3)
ClassLimit
As specified by the equipment user or supplier and more stringent than class 1
≤ 0.01 mg/m³ total oil
≤ 0.1 mg/m³ total oil
≤ 1 mg/m³ total oil
≤ 5 mg/m³ total oil
> 5 mg/m³ total oil

All concentrations at the ISO 8573-1 reference conditions: 20 °C, 100 kPa absolute (1 bar(a)), relative water vapour pressure 0. PDP = pressure dew point.

Your specification

Results appear here when JavaScript is enabled.

ISO 8573-1:2010 [X:X:X]

Particles
Water
Oil

Treatment typically needed Typical, not a design

    Carry these results into a quote

    How the notation works

    ISO 8573-1:2010 grades compressed air for three contaminants and writes the result as three digits in a fixed order:particles : water : oil. A specification reads, for example, ISO 8573-1:2010 [2:4:2]. Lower numbers are cleaner, X means no limit for that contaminant, and each digit is chosen independently.

    • Particles: classes 1–5 count particles per cubic metre in three size bands, and every band in a class must be met. Classes 6, 7 and X use mass concentration instead.
    • Water: classes 1–6 are set by pressure dew point, the temperature at which water condenses at line pressure. Classes 7–9 and X limit liquid water instead.
    • Oil: total oil, meaning aerosol, liquid and vapour added together. For the strictest classes, measurement has to include vapour.
    • Class 0 exists for all three. It is whatever limit the user or supplier specifies, provided it is stricter than class 1.
    • The class applies where the air is specified or measured. Measurement methods are in other parts of the series: ISO 8573-2 (oil aerosol), -3 (humidity), -4 (particles) and -5 (oil vapour).

    Typical applications Typical, confirm with your process owner

    What usually matters for common uses. The class itself is set by your process, your equipment supplier or your sector code, never by this list.

    General plant air
    Tools, actuators and blowing. Water matters most: condensate in the lines corrodes pipe and washes lubricant out of tools. In humid climates a dryer is usually the first treatment step.
    Instrument and control air
    Air must stay dry at the coldest point of the line and carry no oil or particles that could block small orifices in positioners and valves.
    Painting and coating
    Oil and water in spray air cause finish defects, so the oil and water classes are usually the strict ones.
    Food and beverage
    Where air touches product or packaging, the class follows your HACCP plan. The British Compressed Air Society publishes food-grade guidance (Best Practice Guideline 102 and its later revision); check the current edition.
    Pharmaceutical and healthcare
    The class is set by your quality system for each use point and is verified by testing, not assumed from the equipment.
    Electronics
    Fine particles, moisture and oil all matter in many assembly and test processes; follow the equipment maker's air specification.

    Need the air to meet a class? Our air treatment range covers dryers and filters, and anair audit includes dew-point measurement at the point of use.

    Sources

    1. ISO 8573-1:2010 Compressed air, Part 1: Contaminants and purity classes (ISO catalogue page) (opens in a new tab)The standard itself. A revision (ISO/AWI 8573-1, edition 4) is in preparation; check for the latest edition before specifying.
    2. ISO 8573-1:2010 public preview (iTeh Standards): Clause 4 reference conditions and Table 1, particle classes (opens in a new tab)
    3. ICS Schneider Messtechnik, Assessing compressed air quality according to ISO 8573 (water classes 0–6 by pressure dew point) (opens in a new tab)
    4. AIRpipe, ISO 8573-1 Compressed Air Cleanliness Class Table (published summary of all three tables) (opens in a new tab)
    5. R. Ochoa (Trace Analytics), Using ISO 8573-1 to Test Compressed Air: Clearing the Confusion, Compressed Air Best Practices, 30 November 2015 (opens in a new tab)Class 0 is not zero contamination; the limit must be stated and be stricter than class 1. Oil classes 0–2 must include vapour.
    6. US DOE / Compressed Air Challenge, Improving Compressed Air System Performance: A Sourcebook for Industry (2003) (opens in a new tab)Dryer dew points used in the treatment notes: refrigerant-type 35–39 °F; twin-tower desiccant typically −40 °F.

    Results are estimates. They are only as good as the inputs and the published rules of thumb behind them, and they are not a quotation or a guarantee of savings. Treatment notes are typical directions for discussion, not a design. Confirm the classes with your process owner and verify by measurement at the point of use. Savings are project-specific. We measure them against a baseline and verify them after implementation; we don't promise a blanket percentage.

    What the explorer does

    “Clean, dry air” means different things to different people. ISO 8573-1:2010 removes the ambiguity by grading compressed air for three contaminants and writing the result as three numbers in a fixed order: particles : water : oil.

    The explorer shows the three class tables, lets you pick one class from each, and returns:

    • the designation, for example ISO 8573-1:2010 [2:4:2];
    • what each class means in plain English;
    • the air treatment typically needed to reach it, as a direction to discuss rather than a design.

    If you already have a specification, paste it in (“1:4:1” or “ISO 8573-1:2010 [2:4:2]”) and the explorer reads it back.

    How the classes work

    Particles. Classes 1—5 cap the number of particles per cubic metre in three size bands (0.1—0.5 µm, 0.5—1 µm and 1—5 µm), and every band in a class must be met. Classes 6, 7 and X use mass concentration instead.

    Water. Classes 1—6 are set by pressure dew point: −70, −40, −20, +3, +7 and +10 °C. Classes 7—9 and X limit liquid water in g/m³, meaning the air has not been dried.

    Oil. Classes 1—4 cap total oil, meaning aerosol, liquid and vapour together: 0.01, 0.1, 1 and 5 mg/m³. For the strictest classes, measurement has to include vapour.

    Class 0 exists for all three contaminants. It is a limit set by the user or supplier that is more stringent than class 1, and it must be stated with the designation. “Class 0” on its own is not a specification.

    All concentrations are at the standard’s reference conditions: 20 °C, 100 kPa absolute and zero relative water vapour pressure.

    How to read the results

    The treatment list follows the air’s path. Oil comes first because it decides the compressor: an oil-free compressor, or an oil-injected screw with coalescing filters and activated carbon for vapour. Water decides the dryer: a refrigerated dryer for classes 4—6, a desiccant dryer for classes 1—3. Particles decide the filter grades and where they sit.

    In Cambodia’s heat and humidity, water is usually the first problem. Air that leaves a dryer at a +3 °C pressure dew point stays dry only while the pipework stays warmer than that. In a tropical plant that usually holds, except where lines pass through chilled or air-conditioned areas. Hot compressor rooms raise dryer inlet temperatures, so dryer sizing has to start from real site temperatures.

    Limits you should know

    • The treatment notes are typical directions, not a design. Equipment is selected from flow, pressure, inlet conditions and the class each use point needs.
    • A class applies where the air is specified or measured. A dryer can meet its rating and the air at a distant use point can still fail, so verification happens at the point of use, using the test methods in ISO 8573-2 to -5.
    • The typical application notes are labelled “typical, confirm with your process owner”. Your HACCP plan, GMP documentation or equipment supplier sets the real requirement.
    • A revision of ISO 8573-1 is in preparation. Check for the latest edition before writing a specification.

    When to call for a measured check

    If you have to prove an air quality class, measure it. An air audit can include dew-point measurement at the point of use, and our design and engineering team builds the treatment train to the class each user needs, no more. Related reading: refrigerated vs desiccant dryers, oil-free vs oil-injected compressors and the industrial air quality guide. The glossary entry for ISO 8573-1 has a short definition.

    FAQ

    Questions engineers ask us

    What does ISO 8573-1:2010 [1:4:1] mean?

    Particles class 1 (no more than 20,000 particles of 0.1–0.5 µm, 400 of 0.5–1 µm and 10 of 1–5 µm per cubic metre), water class 4 (pressure dew point +3 °C or lower) and oil class 1 (no more than 0.01 mg/m³ of total oil, including vapour).

    Is class 0 the cleanest possible air?

    Class 0 means a limit specified by the equipment user or supplier that is more stringent than class 1. It is not zero contamination, and a class 0 claim means nothing unless the agreed limit is stated with it.

    Which dryer do I need for water class 4?

    Usually a refrigerated dryer rated at a pressure dew point of +3 °C or lower. The US DOE / CAC sourcebook quotes 35–39 °F (about 2–4 °C) for refrigerant-type dryers, so check the rating against the class limit. Classes 1–3 need a desiccant dryer.

    Does an oil-free compressor guarantee oil class 0 or 1?

    Not on its own. ISO 8573-1 oil classes count total oil, including vapour, and intake air can carry hydrocarbons in. The class has to be verified by measurement at the point where it is specified.

    What class does my process need?

    Your process owner, your equipment supplier or your sector code sets it. For food and beverage, the British Compressed Air Society publishes guidance; check its current edition. We can help translate a requirement into a treatment train and verify it.

    Next step