What the explorer does
“Clean, dry air” means different things to different people. ISO 8573-1:2010 removes the ambiguity by grading compressed air for three contaminants and writing the result as three numbers in a fixed order: particles : water : oil.
The explorer shows the three class tables, lets you pick one class from each, and returns:
- the designation, for example
ISO 8573-1:2010 [2:4:2]; - what each class means in plain English;
- the air treatment typically needed to reach it, as a direction to discuss rather than a design.
If you already have a specification, paste it in (“1:4:1” or “ISO 8573-1:2010 [2:4:2]”) and the explorer reads it back.
How the classes work
Particles. Classes 1—5 cap the number of particles per cubic metre in three size bands (0.1—0.5 µm, 0.5—1 µm and 1—5 µm), and every band in a class must be met. Classes 6, 7 and X use mass concentration instead.
Water. Classes 1—6 are set by pressure dew point: −70, −40, −20, +3, +7 and +10 °C. Classes 7—9 and X limit liquid water in g/m³, meaning the air has not been dried.
Oil. Classes 1—4 cap total oil, meaning aerosol, liquid and vapour together: 0.01, 0.1, 1 and 5 mg/m³. For the strictest classes, measurement has to include vapour.
Class 0 exists for all three contaminants. It is a limit set by the user or supplier that is more stringent than class 1, and it must be stated with the designation. “Class 0” on its own is not a specification.
All concentrations are at the standard’s reference conditions: 20 °C, 100 kPa absolute and zero relative water vapour pressure.
How to read the results
The treatment list follows the air’s path. Oil comes first because it decides the compressor: an oil-free compressor, or an oil-injected screw with coalescing filters and activated carbon for vapour. Water decides the dryer: a refrigerated dryer for classes 4—6, a desiccant dryer for classes 1—3. Particles decide the filter grades and where they sit.
In Cambodia’s heat and humidity, water is usually the first problem. Air that leaves a dryer at a +3 °C pressure dew point stays dry only while the pipework stays warmer than that. In a tropical plant that usually holds, except where lines pass through chilled or air-conditioned areas. Hot compressor rooms raise dryer inlet temperatures, so dryer sizing has to start from real site temperatures.
Limits you should know
- The treatment notes are typical directions, not a design. Equipment is selected from flow, pressure, inlet conditions and the class each use point needs.
- A class applies where the air is specified or measured. A dryer can meet its rating and the air at a distant use point can still fail, so verification happens at the point of use, using the test methods in ISO 8573-2 to -5.
- The typical application notes are labelled “typical, confirm with your process owner”. Your HACCP plan, GMP documentation or equipment supplier sets the real requirement.
- A revision of ISO 8573-1 is in preparation. Check for the latest edition before writing a specification.
When to call for a measured check
If you have to prove an air quality class, measure it. An air audit can include dew-point measurement at the point of use, and our design and engineering team builds the treatment train to the class each user needs, no more. Related reading: refrigerated vs desiccant dryers, oil-free vs oil-injected compressors and the industrial air quality guide. The glossary entry for ISO 8573-1 has a short definition.