Solution

Hold the humidity your product needs, every day of the wet season

Industrial humidity control keeps moisture in production areas, warehouses and clean spaces at the level your product and process need, despite tropical outdoor air that stays warm and humid all year. Nexus Turnkey defines the target condition, calculates the moisture load, tightens the envelope, then selects refrigerant or desiccant-rotor dehumidification from the AirMax range and integrates it with your cooling and ventilation. Sensors and data logging show the condition is held, shift after shift.

High-bay warehouse with pallet racking and a polished concrete floor

The problem: tropical air carries moisture into everything

Outdoor air in Cambodia is warm and humid for most of the year, and in the wet season it is close to saturated for long periods. Every open door, every gap in the cladding and every fresh-air intake brings that moisture inside. Once it is in, it ends up in your product.

The damage depends on the industry. In garment and textile plants, fabric and finished goods pick up moisture, which affects handling and weight and invites mould in storage. In warehouses, cartons soften, labels lift and metal parts corrode. Pharmaceutical manufacturers handle powders and tablets that absorb water and change behaviour. Food producers see caking, stickiness and shorter shelf life. Electronics assembly has moisture-sensitive components that need controlled storage.

The usual first response is more air conditioning. It often disappoints. An air conditioner is designed to control temperature. It removes moisture only as a by-product of cooling, and only while it runs. In a space with a modest heat load, or with equipment that is oversized and cycles on and off, the temperature can look right while humidity climbs.

Temperature is what people feel. Humidity is what the product feels.

Our approach: define, calculate, seal, select, prove

Define the target. We agree the condition each zone needs: a relative humidity band, a temperature and, for drier processes, a dew point. The target comes from your product data, your customer’s specification or your quality system. It is not guessed.

Calculate the moisture load. We add up where the moisture comes from: infiltration through the envelope, door openings, ventilation air, people, wet processes and moisture released by the product itself. The design case is the wet season at full production, because that is when the system has to work hardest.

Seal before you size. Every kilogram of water kept out is one the dehumidifier does not have to remove, every hour, for years. We survey the envelope and recommend practical measures: door discipline, fast-acting doors or strip curtains, air locks for busy openings, and sealing of obvious gaps.

Select the technology. Two technologies cover most needs.

  • Refrigerant (condensing) dehumidifiers cool the air below its dew point so moisture condenses, then return it to the space. They suit warm spaces with moderate targets, such as garment stores and general warehouses.
  • Desiccant rotor dehumidifiers adsorb moisture onto a slowly rotating wheel, which is regenerated with heated air. They reach lower dew points and keep working at low temperatures, which suits pharmaceutical areas, cold stores and dry rooms.

Some sites use both, with a desiccant unit treating fresh air and refrigerant units handling the space.

Distribute and integrate. Dry air has to reach the whole space. We design ducted supply and return so there are no damp corners, and we coordinate the dehumidifiers with existing AHUs and cooling so the systems do not fight each other.

Control and prove. Sensors in each zone, a controller that responds to humidity rather than a timer, alarms when conditions drift, and logged data you can show an auditor.

What’s included

A humidity control project covers the survey and moisture-load calculation, envelope recommendations, equipment selection, ducting and air distribution, electrical and controls, condensate drainage, installation, commissioning against the agreed target and operator training. The scope table on this page sets out each element.

We supply the AirMax dehumidifier range as authorised distributor. That covers portable, commercial, ducted, ceiling-mounted, swimming pool, desiccant rotor and low-temperature units. See industrial dehumidifiers for the families. Filters for the dehumidifiers and air-handling plant come from our filters and media range.

How this fits with the rest of your plant

Humidity, temperature and ventilation are one problem. If your plant also needs process cooling or comfort cooling, we design HVAC and cooling and dehumidification together so each does its own job. In clean areas, humidity control works alongside the filtration and positive pressure covered under air quality and emissions. And compressed air has a humidity problem of its own: moisture in the air lines is handled by dryers, specified by pressure dew point under compressed air systems.

The industries we see this most in are garment and textile, warehousing and logistics, pharmaceutical and healthcare, food and beverage and electronics.

After commissioning, a maintenance contract keeps filters, coils, rotors and sensors in condition, and sensor checks keep the logged data trustworthy.

Commissioning against the target, not the nameplate

A dehumidifier that runs is not proof that a space is controlled. We commission against the condition agreed at the start. Sensors are checked before they are trusted, controllers are set to the target band, and the space is logged across normal operation, including door traffic and shift changes. Where the project allows, we review performance again once the wet season arrives, because that is the design case and the real test.

You receive the logged data, the settings and a simple routine for checking sensors and cleaning filters. If the condition drifts later, the trend usually shows why: a door left open, a filter that needs changing, a new moisture source in the space. The data turns an argument about whether it is damp into a fact you can act on.

Standards literacy

Humidity targets usually come from product specifications, customer requirements or a site’s quality system rather than a single standard. In controlled environments, humidity is often specified alongside particle cleanliness classified under ISO 14644-1. We work from whichever requirement applies to you and design the monitoring to demonstrate it.

For the full method, technologies and worked examples, read our industrial dehumidification guide.

Scope

What's included

What a humidity control project includes
ElementWhat it coversWhat we design for
Target conditionRelative humidity, temperature and, where needed, dew point for each zoneWhat the product, process or stored goods actually tolerate
Moisture loadInfiltration, door openings, outdoor air, people, wet processes and the product itselfThe worst realistic case, typically the wet season at full production
EnvelopeSealing, door strategy, air locks and vapour barriersKeeping moisture out before paying to remove it
DehumidificationPortable, commercial, ducted, ceiling-mounted, desiccant rotor and low-temperature unitsThe right technology for the target dew point and space temperature
Air distribution and integrationDucting, supply and return positions, interface with AHUs and coolingEven conditions across the space; no fighting between systems
Control and monitoringHumidity and temperature sensors, controllers, alarms, data loggingProof that the condition is held, and an early warning when it is not

FAQ

Questions engineers ask us

Can our air conditioning not control the humidity on its own?

Sometimes, but often not well. Cooling coils remove moisture only while they run and only when the coil is colder than the air's dew point. When the cooling load is low, or the system is oversized and cycles on and off, humidity drifts up while the temperature looks fine. Dedicated dehumidification controls moisture independently of temperature.

What is the difference between a refrigerant and a desiccant dehumidifier?

A refrigerant dehumidifier cools air below its dew point so moisture condenses, then reheats it. It works well in warm spaces at moderate humidity targets. A desiccant rotor dehumidifier adsorbs moisture onto a rotating wheel that is continuously dried by heated air. It reaches lower dew points and keeps working in cool spaces where a refrigerant unit struggles.

What humidity should a warehouse or garment store be kept at?

It depends on what is stored. Many goods are protected from mould and corrosion by keeping relative humidity steadily below the level where mould grows, but the exact figure depends on the product and its packaging. We agree a target with you, based on your product's requirements or your customer's specification, before sizing anything.

Do we need to seal the building first?

Usually some sealing pays for itself quickly. Every gap and open door lets humid outdoor air in, and the dehumidifier has to remove that moisture continuously. We survey the envelope and recommend practical measures, such as door strategy, strip curtains or air locks, before sizing equipment.

How do we know the system is working?

We install humidity and temperature sensors in the controlled zones and log the data. You can see trends, set alarms when conditions drift, and show customers or auditors that storage or production conditions were held. The data can also feed AirSight.

Which dehumidifiers do you supply?

We supply the AirMax dehumidifier range as authorised distributor: portable, commercial, ducted, ceiling-mounted, swimming pool, desiccant rotor and low-temperature units. We select the type and size from your moisture load.

Next step

Get a dehumidification proposal for your site

Tell us the space, what is stored or made there, and what goes wrong in the wet season. We will propose a target condition and how to hold it.