AirMax regenerative thermal oxidisers (RTO)
Fully automatic RTOs that destroy VOCs by high-temperature oxidation and recover most of the heat in ceramic beds.
Indicative range: Typically ≈10,000–200,000 CMH; depends on the application
Products · AirMax
A VOC treatment system has to be matched to what is actually in the exhaust: which compounds, how concentrated, at what airflow and temperature. Nexus Turnkey supplies the AirMax air quality range as technology partner and authorised distributor, covering activated-carbon units and towers, zeolite rotor concentrators, regenerative thermal oxidisers, packed-bed, venturi and wet scrubbers, cartridge and bag dust collectors, cyclones, cleanroom equipment, odour control and monitoring. We characterise the exhaust first, then design, install and commission the system.
How to choose
| What is in the air | Usual technology | Where it fits | Watch for |
|---|---|---|---|
| VOCs at low concentration, modest airflow | Activated-carbon units or towers | Printing, coating and small paint lines | Carbon saturation; change-out cost |
| VOCs at low concentration, high airflow | Zeolite rotor concentrator, often followed by an oxidiser | Paint shops, printing, coating, footwear | Pre-filtration to protect the rotor |
| VOCs at higher concentration | Regenerative thermal oxidiser (RTO) | Coating, chemical and printing exhaust | Fuel use at low concentration; safety interlocks |
| Acid or alkaline gases, mists, odours | Packed-bed, venturi or wet scrubber | Chemical, plating, rendering and wastewater | Scrubber liquor treatment and disposal |
| Dust and particulate | Cartridge or bag dust collector, cyclone pre-separator | Cement, rice and feed mills, grinding, welding, wood | Explosion risk with combustible dusts |
Families
Fully automatic RTOs that destroy VOCs by high-temperature oxidation and recover most of the heat in ceramic beds.
Indicative range: Typically ≈10,000–200,000 CMH; depends on the application
Compact pulse-jet cartridge collectors for fine dust from cement handling, grinding and welding.
Activated-carbon units and towers that adsorb VOCs and odours from exhaust air at low concentrations.
Indicative range: Towers: typically ≈2,000–20,000 CMH per unit; depends on the application
Scrubbers that absorb acid and alkaline gases, capture mists and fumes, and remove odours using a liquid chosen for the pollutant.
Zeolite rotor concentrators that turn a large, dilute VOC exhaust into a small, concentrated stream that is cheaper to destroy.
Bag filter collectors for high dust loads in rice mills, feed mills and other bulk handling plants.
Cyclones that spin coarse dust, husk and chips out of the air with no filter media, alone or ahead of a filter.
HEPA H13/H14 filtration, laminar flow units and pass boxes for clean areas that must keep contamination out.
Odour control using activated carbon, bio-filters or chemical scrubbers, matched to the compounds causing the smell.
Sensors and displays that measure the air in workplaces and around treatment systems, locally or through Nexus AirSight.
Ranges are indicative. Confirm against the current manufacturer datasheet.
Two factories can both say they have a VOC problem and need completely different equipment. One prints packaging with a few solvents at high airflow and low concentration. Another runs a coating oven with a concentrated, hot exhaust. The technology that is economical for one is wasteful for the other. So we start by characterising the air: which compounds, at what concentration, at what airflow and temperature, with what dust or moisture alongside.
Nexus Turnkey is technology partner and authorised distributor for AirMax, and supplies its air quality and emissions range:
The table above gives the first cut. In more detail:
Each product page gives typical performance figures as indicative ranges. Actual performance depends on the application, and we state it for your exhaust after characterisation. The industrial air quality guide and our article on VOC control with activated carbon, zeolite and RTO go further.
High ambient humidity matters here. Moist air competes with VOCs for space on activated carbon and can reduce its capacity, so humid exhausts may need conditioning first. Dust from cement, rice and feed handling is fine, abrasive and sometimes combustible, so collectors need the right media, cleaning system and explosion protection. Our article on dust collection for cement, rice and feed mills covers those cases.
We characterise the exhaust, select the AirMax technology, design the ducting, fans, controls and safety systems, then install and commission. Performance is measured at handover against the agreed design basis. After that we supply consumables such as carbon, filter cartridges and bags, and maintain the system under a planned contract. Monitoring can feed Nexus AirSight on our SCADA and monitoring page.
FAQ
By concentration and airflow. Activated carbon suits low concentrations at modest airflow. A zeolite rotor concentrates a large, dilute airflow into a small, rich one that is cheaper to destroy. An RTO destroys VOCs by oxidation and suits higher concentrations. Many plants use a rotor and an oxidiser together.
It depends on the compounds, their concentration, the airflow and how the system is maintained. Typical figures are given on each product page as indicative only. We state an expected performance for your exhaust after we have characterised it.
We need to know what is in the exhaust. Solvent consumption records, safety data sheets and airflow measurements are often enough to start. For a firm design we may recommend sampling.
Combustible dusts such as flour, grain, wood and some powders can explode. We identify the risk at design stage and include the protection the application calls for, such as explosion venting, isolation and earthing, and keep ignition sources out of the collector.
Yes. Sensors for parameters such as particulates, TVOC, temperature and humidity can report to a local display or to Nexus AirSight, our monitoring overlay, so EHS and production see the same numbers.
Next step
Send the process, the solvents or dusts involved and the exhaust fan details. We will tell you which technologies are worth evaluating.