Phnom Penh, serving Cambodia and the region

Solution

Capture it at the source, treat it to the limit, prove it on a screen

Industrial air pollution control in Cambodia starts with characterising what leaves your process: VOCs, dust, acid gases, odour or fumes, at what flow, temperature and concentration. Nexus Turnkey then designs capture at the source, selects the treatment technology that fits the stream (activated carbon, zeolite concentrators, RTOs, scrubbers, dust collectors or cleanroom filtration), and adds monitoring so you can see performance. We supply the AirMax range as technology partner and authorised distributor, and one team answers for the result.

Large galvanised ventilation ducts running along a building

The problem: emissions are a process problem, not a chimney problem

Most air quality complaints arrive as a symptom. A neighbour smells solvent. Dust settles on the roof. Workers in the coating line complain of headaches. A customer audit asks for emissions data that nobody has. The first instinct is often to buy a filter or a scrubber and fit it to the stack.

That rarely works on its own. Treatment equipment is selected for a particular stream: its airflow, temperature, humidity, the pollutant and its concentration, and how all of these change across a shift. Fit the wrong technology and it either fails to treat the load or costs far more to run than it should. Undersize the capture hoods and the pollutant never reaches the treatment at all. It escapes into the workspace instead.

Industries in Cambodia meet this in different forms. Printing and coating lines emit solvent VOCs. Cement, rice and feed mills generate dust. Chemical processes release acid gases and odours. Pharmaceutical and electronics areas need the opposite problem solved: keeping particles out.

Our approach: characterise, capture, treat, monitor

1. Characterise the stream. We start by understanding what leaves the process. We look at the sources, the airflow at each, temperature and humidity, the pollutant species, their concentration and how it varies over time, and any particulate that would foul downstream media. Where specialist stack sampling is needed, we plan it rather than assume.

2. Capture at the source. The cheapest air to treat is air you never had to move. We design hoods, enclosures and ducting to capture emissions close to where they are released. That keeps the total airflow, and with it the size and running cost of the treatment system, as low as practical.

3. Treat with the right technology. Each technology has a range where it makes sense.

  • Activated carbon adsorbs VOCs and odours. It suits lower concentrations and intermittent operation, and media replacement is the main running cost.
  • Zeolite rotor concentrators take a large, dilute airflow and concentrate the VOCs into a much smaller stream. That makes final treatment smaller and cheaper to run.
  • A regenerative thermal oxidiser (RTO) destroys VOCs at high temperature. Its ceramic beds recover much of the heat, which suits continuous, higher-concentration loads.
  • Packed-bed, venturi and wet scrubbers remove acid gases, mists, fumes and soluble odours with a circulating liquid.
  • Dust collectors remove particulate. Cartridge units suit fine dust from cement handling, grinding and welding. A baghouse suits high dust loads such as rice and feed milling. A cyclone takes out coarse material first.

4. Monitor and prove it. We add sensors and displays for the parameters that matter, such as TVOC, PM2.5, differential pressure across filters and fan status. These can feed AirSight so EHS and production see the same numbers.

The right treatment system is the one sized to your measured stream, not the largest one on the price list.

What’s included

A typical project covers the measurement and design study, capture hoods and ducting, fans, the treatment equipment, stacks, electrical and controls, monitoring, installation, commissioning and operator training. The scope table on this page shows how problems map to technologies. Indicative performance ranges for each technology are given on the air quality and emissions products page, and the real figure for your plant is confirmed against your measured stream.

We supply the AirMax air quality and environmental control range as technology partner and authorised distributor. Fans and blowers come from the matching duty, and replacement media from our filters and media range.

Clean and protected spaces

Some areas need clean air in, not dirty air out. Pharmaceutical filling, electronics assembly and some food packaging areas need controlled particle levels. We design HEPA filtration, laminar flow units, pass boxes and positive-pressure ventilation, so filtered air flows from clean areas towards less clean ones.

Before we design a clean space, we agree

  • The cleanliness class or particle limit the process needs
  • Which rooms sit at which pressure, and in what order
  • Air change rate and filter positions
  • How people and materials enter (gowning, pass boxes)
  • How performance will be checked at handover and afterwards

How this fits with the rest of your plant

Emissions systems share power, controls and often plant-room space with compressed air and HVAC. Treatment fans add to the electrical load, and positive-pressure areas interact with the building’s cooling. Because we are responsible for every kind of air on the site, we plan those interfaces once. Compressed air for dust-collector pulse cleaning comes from the same compressed air system we design. Temperature and humidity in clean areas link to humidity control and HVAC and cooling.

The industries that most often need this work are printing and coating, chemicals, cement and building materials, agro-processing and pharmaceutical and healthcare.

Standards literacy

For a deeper explanation of technologies, filter classes and monitoring, read our industrial air quality guide.

Scope

What's included

What an air quality and emissions project can include
ProblemTypical technologiesWhat we design for
Solvent and VOC emissions (TVOC)Activated-carbon filtration units and adsorption towers, zeolite rotor concentrators, regenerative thermal oxidisers (RTO)Species, concentration and airflow; solvent load; operating hours; energy use of the treatment itself
Acid gases, mists and chemical fumesPacked-bed scrubbers, venturi scrubbers, wet scrubbersGas solubility, liquid chemistry, blowdown handling and materials that survive the stream
Process dustCartridge collectors, bag filters (baghouses), cyclone pre-separatorsDust type and loading, particle size, moisture, explosion risk where relevant, cleaning cycle
OdourActivated carbon, bio-filters, chemical scrubbersOdour source and chemistry, neighbour exposure, media life
Clean and protected spacesHEPA filtration, laminar flow units, pass boxes, positive-pressure ventilationThe cleanliness class required, pressure cascade and air change rate
Visibility and proofAir quality sensors, displays and data logging via AirSightThe parameters that matter to your process, your workforce and your permit

FAQ

Questions engineers ask us

Which VOC treatment technology is right for my plant?

It depends mainly on airflow, VOC concentration and operating hours. Activated carbon suits lower concentrations and intermittent loads. Zeolite rotor concentrators reduce large, dilute airflows to a small, concentrated stream. RTOs destroy VOCs thermally and suit continuous, higher loads. Often the answer is a combination, such as a concentrator feeding an oxidiser. We decide after characterising the stream.

Do you measure the emissions before proposing a system?

Yes. A proposal without data is a guess. We gather airflow, temperature, humidity and, where possible, concentration data from your exhaust points, and review your process and solvent consumption. Where specialist stack sampling is required, we say so and plan for it.

Can one system handle both dust and VOCs?

Usually the stream needs staged treatment. Dust and sticky particulates are removed first so they do not blind carbon or zeolite media, then the gaseous fraction is treated. We design the whole train, including pre-filtration, so each stage protects the next.

What emission limits do you design to?

We design to the limits and conditions that apply to your site, as stated in your environmental approval or by your customer's requirements. Tell us what you have been asked to meet and we will design a system to meet it, with monitoring to show it.

What is the difference between a cleanroom and positive pressure?

A cleanroom controls airborne particle concentration to a defined class, typically with HEPA filtration and controlled air changes. Positive pressure is one of the tools used: the clean space is held at a higher pressure than its surroundings so air leaks outwards, not in. Many production areas need positive pressure without needing a full cleanroom classification.

Who maintains the system after installation?

We can. Treatment performance depends on media condition, fan performance and control settings. A maintenance contract covers inspections, media replacement planning and performance checks so the system keeps doing what it was designed to do.

Next step

Tell us what your exhaust carries

Describe the process, the pollutant and the airflow if you know it. We will propose how to characterise it and what to treat it with.