Air-cooled chillers (scroll and screw)
Air-cooled chillers with scroll or screw compressors, for process and comfort cooling without a cooling tower.
Products · Nexus
A chiller in Cambodia works against high ambient temperatures and high wet-bulb conditions for most of the year, so selection has to start from real site conditions, not catalogue ratings. Nexus Turnkey supplies the Nexus range of air-cooled and water-cooled chillers, air handling units, industrial ventilation and exhaust fans, cooling towers and evaporative air coolers. Capacities are selected to your load, and we install, commission and maintain the system with HVAC spare parts support.
How to choose
| Your situation | Usual direction | Why | Watch for |
|---|---|---|---|
| Small to medium load, limited water or space for towers | Air-cooled chiller | No cooling tower, water treatment or condenser pumps | Capacity and efficiency fall as ambient rises |
| Large, steady load with space for a plant room | Water-cooled screw chiller with cooling tower | Rejects heat to the wet-bulb, usually more efficient at high ambient | Water treatment and tower maintenance |
| Conditioned air for production or clean areas | Air handling unit on chilled water | Controls temperature, humidity, filtration and fresh air together | Coil and filter access for maintenance |
| Hot workshop, heat and fumes to remove | Industrial ventilation and exhaust fans | Air changes remove heat and contaminants at low running cost | Make-up air path and dust ingress |
| Spot cooling for people in semi-open buildings | Evaporative air coolers | Low running cost per area cooled | Less effective in very humid weather |
Families
Air-cooled chillers with scroll or screw compressors, for process and comfort cooling without a cooling tower.
AHUs that filter, cool, dehumidify and supply conditioned fresh air to production, clean and occupied areas.
Water-cooled screw chillers for large, steady cooling loads, rejecting heat through a cooling tower.
Industrial fans that remove heat, fumes and humid air from production halls and supply make-up air.
Cooling towers that reject heat from water-cooled chillers and process equipment by evaporation, selected for high wet-bulb conditions.
Evaporative coolers for spot and zone cooling of people in large, ventilated buildings, at low running cost.
Ranges are indicative. Confirm against the current manufacturer datasheet.
Cooling equipment in Cambodia rarely gets a rest. High dry-bulb temperatures raise the condensing pressure on air-cooled machines, and high humidity raises the wet-bulb temperature that cooling towers work against. Equipment chosen from brochure ratings at milder conditions can fall short exactly when production needs it most.
Nexus Turnkey supplies the Nexus range:
Capacities are selected to your load. Ask for a datasheet.
Every cooling decision starts with the load. We build it from process heat, building and solar gains, people, fresh air and equipment, at design conditions for your site. Then we look at how it varies. A plant that runs well below peak for most of the day needs a different chiller arrangement from one that runs flat out, and multiple chillers or variable-speed compressors can keep COP high at part load.
The table above sets the first direction. The key trade-off is heat rejection. An air-cooled chiller rejects heat to the outdoor dry-bulb temperature. A water-cooled chiller with a cooling tower rejects heat to the wet-bulb temperature, which is lower, so it usually runs more efficiently, at the cost of water, water treatment and tower maintenance. We compare both on your load and conditions, using the EER and COP at your duty points rather than headline ratings.
Our chiller maintenance checklist for hot climates lists the checks that keep capacity up through the hot season.
We calculate the load, select the Nexus range equipment, design the chilled-water and condenser-water systems, ductwork and controls, then install and commission. Chillers and AHUs can report to Nexus AirSight on our SCADA and monitoring page alongside compressed air. After handover we provide planned maintenance, coil cleaning, refrigerant checks, water treatment coordination and spare parts. Savings are project-specific. We measure them against a baseline and verify them after implementation; we don’t promise a blanket percentage.
FAQ
Air-cooled chillers are simpler to install and need no cooling tower or water treatment, which suits small and medium loads. Water-cooled chillers reject heat through a cooling tower to the wet-bulb temperature, which is lower than dry-bulb, so they are usually more efficient on large, steady loads. The choice also depends on water availability, space and maintenance capability.
From the cooling load: process heat, building and solar gains, people, fresh air and equipment, at the design conditions for your site, plus any planned growth. We also look at how the load varies through the day, because part-load efficiency often matters more than full-load rating.
Air-cooled condensers work against the outdoor air temperature. As it rises, condensing pressure rises, capacity falls and power climbs. Dirty condenser coils, hot-air recirculation around the unit and low refrigerant charge make it worse. A maintenance check usually finds the cause.
They work best in dry air. In humid weather the temperature drop they can achieve is smaller. They are still useful for spot cooling people in large, ventilated buildings, but they are not a substitute for a chiller where temperature or humidity must be controlled.
Capacities are selected to your load. Ask for a datasheet for your duty.
Yes. We supply spares for the Nexus range and can source many common HVAC parts for installed equipment, confirmed by part number before ordering.
Next step
Send the equipment you have, the load you think you need and the symptoms in the hot season. We will tell you what we would check and what we would propose.