Toolkit · Compressed air cost

See what your compressor costs to run, including the hours it makes no air

A compressed air cost calculator estimates a compressor's annual electricity use and cost from its motor rating, motor efficiency, hours, and the share of time it runs loaded and unloaded. This one uses the part-load equation in the US DOE / Compressed Air Challenge sourcebook: input power = motor rating ÷ efficiency, and annual kWh = input power × hours × (loaded share + unloaded power share × unloaded share). It splits energy into loaded and unloaded running, and, if you enter free air delivery, adds specific power and the real energy per cubic metre. The tariff starts at EDC's published industrial rate at medium voltage (USD 0.137/kWh) and can be replaced with your own; cost results include a 10 % service fee. The result is an estimate, and logged power data is better.

Your inputs

Prefilled with the US DOE sourcebook's worked example (a 100 hp, about 75 kW, compressor running all year, 65 % loaded and 35 % unloaded). Replace every value with your own.

Units
kW

Motor nameplate (shaft) rating. If the motor runs into its service factor, use the higher figure; the compressor datasheet shows it.

%

%

Running but making no air. The rest of the time it is off.

h/yr

USD/kWh

Prefilled with EDC's published industrial tariff at medium voltage (USD 0.137/kWh, Electricity Authority of Cambodia, 2024). Replace it with the all-in rate from your bill. Cost results include a 10 % service fee.

Assumptions and optional flow
%

DOE: 20–30 % is a good estimate for fully unloaded rotary screw compressors and 10–15 % for reciprocating ones; its example uses 30 %. Your compressor's data is better.

%

DOE's equation assumes 90 %. Use the nameplate value; DOE suggests about 80 % for older, rewound motors.

m³/min

Adds specific power and the real cost per cubic metre. Use the FAD at your working pressure.

Results

Results appear here when JavaScript is enabled.

—Estimated electricity cost per year
Energy
—kWh/yr
Input power, loaded
—kW
Average power
—kW
Spent unloaded
—

Where the energy goes

  • Loaded: making air—
  • Unloaded: running, no air—

Carry these results into a quote

How it's calculated

We use the part-load equation from the US DOE / Compressed Air Challenge sourcebook:

input kW = motor rating (kW) ÷ motor efficiency [hp × 0.7457 = kW] annual kWh = input kW × hours × [ loaded share + unloaded power share × unloaded share ] annual cost = annual kWh × USD per kWh

  • DOE's worked example (100 hp, 90 % motor, 8,760 h, 65 % loaded, 35 % unloaded at 30 %, USD 0.05/kWh) gives USD 27,410 a year. This calculator returns the same to within 0.05 %, because we use the exact 0.7457 kW per hp where DOE rounds to 0.746.
  • Specific power = input kW at full load ÷ free air delivery. Effective energy (kWh/m³) divides all the energy, including unloaded running, by the air actually delivered, so it shows what poor part-load control costs per cubic metre.
  • The equation covers load/unload (and start/stop) machines. For variable-speed or modulating control, part-load power follows the manufacturer's curve, so use logged kW instead.
  • Demand charges, power factor and auxiliary loads (dryers, fans) are not included; DOE's sourcebook recommends adding auxiliary motor ratings for a fuller picture.

Sources

  1. US DOE / Compressed Air Challenge, Improving Compressed Air System Performance: A Sourcebook for Industry (DOE/GO-102003-1822, November 2003), section 12: Compressed Air System Economics (opens in a new tab)Part-load cost equation; 90 % motor efficiency assumption; unloaded factor 0.20–0.30 for rotary screw compressors (0.30 in the worked example).
  2. NIST Special Publication 811 (2008), Appendix B.8: conversion factors (opens in a new tab)Horsepower (550 ft·lbf/s) to watts; cubic feet to cubic metres.

Results are estimates. They are only as good as the inputs and the published rules of thumb behind them, and they are not a quotation or a guarantee of savings. Load and unload percentages are best read from the compressor controller's running-hour counters or from logged data. Savings are project-specific. We measure them against a baseline and verify them after implementation; we don't promise a blanket percentage.

What the calculator does

Electricity is usually the largest cost of owning a compressor over its life, and much of it is invisible. A compressor on load/unload control keeps its motor running after it stops making air, so a share of the bill buys nothing.

This calculator estimates that bill. It uses the part-load equation published in the US DOE / Compressed Air Challenge sourcebook, Improving Compressed Air System Performance:

input kW    = motor rating ÷ motor efficiency
annual kWh  = input kW × hours × (loaded share + unloaded power share × unloaded share)
annual cost = annual kWh × tariff

It then splits the energy into loaded running (making air) and unloaded running (motor turning, no air), and shows how much of the total is spent unloaded.

How to use it

  1. Pick units. kW and m³/min, or hp and cfm. Values convert when you switch.
  2. Motor rating. The full-load shaft rating from the nameplate. If the motor runs into its service factor, the sourcebook advises using the higher figure, so check the compressor datasheet.
  3. Loaded and unloaded time. Read them from the controller’s hour counters. Whatever is left over is time the compressor is stopped.
  4. Hours per year. The hours the compressor is available to run. 8,760 is continuous.
  5. Tariff. Your all-in rate from a recent bill. We don’t prefill one.
  6. Assumptions. Unloaded power (default 30 % of full load, the sourcebook’s example figure) and motor efficiency (default 90 %, the sourcebook’s assumption). Replace both with your machine’s data where you have it.
  7. Free air delivery (optional). Enter the FAD at your working pressure to add specific power and energy per cubic metre.

The form opens with the sourcebook’s worked example (100 hp, about 75 kW, 65 % loaded, 35 % unloaded, 8,760 h) so you can see how it works. Replace every value with your own.

How to read the results

  • Cost or energy per year. The headline. Without a tariff you see kWh.
  • Input power, loaded is what the motor draws at full load.
  • Average power is total energy divided by hours, a useful check against a power logger.
  • Spent unloaded is the share of energy that made no air. A high figure points to load/unload cycling on an oversized machine, too little receiver storage, or controls that need attention.
  • Specific power (with FAD) is input kW divided by delivered air at full load. Effective energy in kWh/m³ divides all the energy, loaded and unloaded, by the air actually delivered. The gap between the two is the cost of part-load running.

Limits you should know

  • The equation suits load/unload and start/stop machines. For VSD and modulating control, part-load power follows the manufacturer’s curve. Use logged kW.
  • Demand charges, power factor and auxiliaries (dryers, cooling fans, drains) are not included. The sourcebook suggests adding auxiliary motor ratings for a fuller picture.
  • Unloaded power is not instant. The sourcebook notes it takes time to reach fully unloaded power, so short unload cycles cost more than the simple factor suggests.

Savings are project-specific. We measure them against a baseline and verify them after implementation; we don’t promise a blanket percentage.

When to call for a measured audit

If the unloaded share is high, or the specific power looks poor, the next step is data. An air audit logs power, pressure and flow across a representative production period, so you know the real load profile before choosing a trim compressor, a sequencer or a VSD. If you are planning new capacity, our design and engineering team sizes it to that profile.

Related: fixed speed vs VSD vs PM-VSD compressors, how to choose an air compressor, and our range of air compressors. To put a number on leaks, use the leak cost calculator.

FAQ

Questions engineers ask us

Why does an unloaded compressor still cost money?

On load/unload control, the motor keeps turning when the compressor stops making air. The US DOE / CAC sourcebook says 0.20–0.30 of full-load power is a good estimate for fully unloaded rotary screw compressors, and uses 0.30 in its example. Over thousands of hours, that adds up.

Where do I find the loaded and unloaded percentages?

Most compressor controllers record running hours and loaded hours. Unloaded time is running hours minus loaded hours. Divide each by the hours in the period. Logged power data from an audit is more accurate still.

Does this work for variable-speed compressors?

Not directly. The equation describes load/unload and start/stop machines. A VSD compressor's power follows its speed and the manufacturer's curve, so measured or logged kW is the right input. You can still use the tool for a rough full-load figure.

What is specific power and why does it matter?

Specific power is input power divided by the air delivered, in kW per m³/min or kW per 100 cfm. It is the cleanest way to compare how efficiently compressors make air. The effective figure here also includes unloaded running, so it shows what poor part-load control costs per cubic metre.

Is the motor rating the same as the power drawn?

No. The motor rating is shaft power; the grid supplies more, because the motor has losses. That is why we divide by motor efficiency. The DOE sourcebook assumes 90 % and suggests about 80 % for older, rewound motors.

Next step