What the calculator does
Compressors work harder to deliver higher pressure. Many plants run higher than they need to, often because the set point was raised years ago to cover a pressure drop or a single demanding machine, and nobody lowered it again.
This tool estimates what bringing that pressure down could be worth. It uses a published rule of thumb from the US DOE / Compressed Air Challenge sourcebook Improving Compressed Air System Performance: for systems in the 100 psig range, every 2 psi of discharge pressure changes energy consumption by approximately 1 % at full output flow.
saving (%) = (current − target, in psi) ÷ 2 × 1 %
kWh saved = annual compressor kWh × saving ÷ 100
cost saved = kWh saved × tariff
2 psi is about 0.14 bar, so near 7 bar g the rule is roughly 7 % per bar. The calculator converts bar to psi for you.
How to use it
- Choose bar g or psig. Values convert when you switch.
- Current and target set pressure. Use the compressor’s discharge or control pressure. The target has to be lower.
- Annual compressor energy. Enter kWh per year from a meter, or switch to average kW × hours. No meter? The compressed air cost calculator gives an estimate.
- Tariff. Your all-in rate from a recent bill. We don’t prefill one.
- Unregulated demand (optional). If you know roughly what share of your air goes to leaks, open blowing or unregulated users, enter it (0—50 %). The sourcebook adds about 0.6—1.0 % per 2 psi when 30—50 % of demand is unregulated, because those users consume less air at lower pressure. We scale that linearly.
How to read the results
- Indicative saving is the cost (or kWh, without a tariff) per year at the rule-of-thumb rate.
- Energy saving % is the percentage applied. With the unregulated option on, a note shows how much came from each part.
- Reduction is shown in bar and psi.
- A caution appears when your current pressure is well outside the range around 100 psig (about 6.9 bar g) that the rule was written for.
Limits you should know
- This is a rule of thumb, applied linearly. The sourcebook itself asks you to check the performance curves for centrifugal and two-stage, lubricant-injected rotary screw compressors.
- Savings depend on how the compressor controls respond to a lower set point. Load/unload, modulating and VSD control behave differently.
- The real constraint is the user who needs the most pressure. If one machine needs more, a booster or a dedicated supply may cost less than holding the whole ring main high.
- Reducing pressure drop across refrigerated dryers, filters and undersized pipework is often what makes a lower set point possible.
Savings are project-specific. We measure them against a baseline and verify them after implementation; we don’t promise a blanket percentage.
When to call for a measured audit
An air audit logs pressure at the compressor and at your critical users across real production, so the new set point comes from data rather than a guess. It also measures leakage, which falls as pressure falls; a leak detection survey can then remove most of the reason the pressure was raised. If the distribution system is the bottleneck, our design and engineering team can size the fix.
Related: what is a compressed air audit, the hidden cost of compressed air leaks, and the energy optimisation solution. Estimate leak losses with the leak cost calculator.