Phnom Penh, serving Cambodia and the region

Toolkit · Pressure reduction savings

Every bar you don't need is energy you don't have to buy

A pressure reduction savings calculator estimates the energy saved by lowering a compressed air system's set pressure. This one applies the US DOE / Compressed Air Challenge rule of thumb: for systems in the 100 psig range, each 2 psi of discharge pressure changes compressor energy by approximately 1 % at full output flow. Enter current and target pressure in bar or psi, your annual compressor energy and your tariff (it starts at EDC's published industrial rate at medium voltage, USD 0.137/kWh; cost results include a 10 % service fee). An optional term adds the sourcebook's extra 0.6–1.0 % per 2 psi where 30–50 % of demand is unregulated. It is a rule of thumb, not a measurement: your compressor's curves and a pressure survey decide what is achievable.

Your inputs

Pressure unit
bar g

bar g

Use the compressor's discharge (control) pressure. The target must still deliver the pressure your highest-pressure user needs, after the pressure drop through dryers, filters and pipework.

Annual compressor energy
kWh/yr

No meter? Estimate it with the compressed air cost calculator.

USD/kWh

Prefilled with EDC's published industrial tariff at medium voltage (USD 0.137/kWh, Electricity Authority of Cambodia, 2024). Replace it with the all-in rate from your bill. Cost results include a 10 % service fee.

Include unregulated demand (optional)
%

Leaks, open blowing and users without regulators consume less air at lower pressure. DOE adds about 0.6–1.0 % per 2 psi when 30–50 % of demand is unregulated; we scale that in a straight line and cap the input at 50 %. Leave at 0 if you don't know.

Results

Results appear here when JavaScript is enabled.

Rule of thumb
—Indicative saving per year
Energy saving
—
kWh saved
—kWh/yr
Reduction
—bar
Reduction
—psi

Carry these results into a quote

How it's calculated

The US DOE / Compressed Air Challenge sourcebook gives this rule of thumb: for systems in the 100 psig range, every 2 psi increase in discharge pressure raises energy consumption by approximately 1 % at full output flow. It asks you to check the performance curves for centrifugal and two-stage, lubricant-injected rotary screw compressors. We apply it in reverse for a reduction:

saving (%) = (current − target, in psi) ÷ 2 × 1 % + optional: (current − target) ÷ 2 × 0.02 × unregulated share (%) kWh saved = annual kWh × saving ÷ 100 USD saved = kWh saved × tariff [1 bar = 14.504 psi]

  • The result is linear and indicative. Real savings depend on compressor type, control mode and part-load behaviour.
  • The rule is stated for systems around 100 psig (about 6.9 bar g). Outside 70–125 psig we show a caution.
  • Lowering pressure only pays if every user still gets the pressure it needs. Reducing pressure drop across dryers, filters and pipework is often what makes a lower set point possible.
  • A measured audit logs pressure at the compressor and at the critical users, so the new set point is chosen from data.

Sources

  1. US DOE / Compressed Air Challenge, Improving Compressed Air System Performance: A Sourcebook for Industry (DOE/GO-102003-1822, November 2003) (opens in a new tab)Rule of thumb for systems in the 100 psig range: about 1 % energy per 2 psi of discharge pressure at full output flow; a further 0.6–1.0 % per 2 psi where 30–50 % of demand is unregulated.
  2. NIST Special Publication 811 (2008), Appendix B.8: conversion factors (opens in a new tab)psi to bar.

Results are estimates. They are only as good as the inputs and the published rules of thumb behind them, and they are not a quotation or a guarantee of savings. The 1 % per 2 psi figure is a rule of thumb for systems around 100 psig (about 7 bar), not a measured result for your compressor. Savings are project-specific. We measure them against a baseline and verify them after implementation; we don't promise a blanket percentage.

What the calculator does

Compressors work harder to deliver higher pressure. Many plants run higher than they need to, often because the set point was raised years ago to cover a pressure drop or a single demanding machine, and nobody lowered it again.

This tool estimates what bringing that pressure down could be worth. It uses a published rule of thumb from the US DOE / Compressed Air Challenge sourcebook Improving Compressed Air System Performance: for systems in the 100 psig range, every 2 psi of discharge pressure changes energy consumption by approximately 1 % at full output flow.

saving (%)  = (current − target, in psi) ÷ 2 × 1 %
kWh saved   = annual compressor kWh × saving ÷ 100
cost saved  = kWh saved × tariff

2 psi is about 0.14 bar, so near 7 bar g the rule is roughly 7 % per bar. The calculator converts bar to psi for you.

How to use it

  1. Choose bar g or psig. Values convert when you switch.
  2. Current and target set pressure. Use the compressor’s discharge or control pressure. The target has to be lower.
  3. Annual compressor energy. Enter kWh per year from a meter, or switch to average kW × hours. No meter? The compressed air cost calculator gives an estimate.
  4. Tariff. Your all-in rate from a recent bill. We don’t prefill one.
  5. Unregulated demand (optional). If you know roughly what share of your air goes to leaks, open blowing or unregulated users, enter it (0—50 %). The sourcebook adds about 0.6—1.0 % per 2 psi when 30—50 % of demand is unregulated, because those users consume less air at lower pressure. We scale that linearly.

How to read the results

  • Indicative saving is the cost (or kWh, without a tariff) per year at the rule-of-thumb rate.
  • Energy saving % is the percentage applied. With the unregulated option on, a note shows how much came from each part.
  • Reduction is shown in bar and psi.
  • A caution appears when your current pressure is well outside the range around 100 psig (about 6.9 bar g) that the rule was written for.

Limits you should know

  • This is a rule of thumb, applied linearly. The sourcebook itself asks you to check the performance curves for centrifugal and two-stage, lubricant-injected rotary screw compressors.
  • Savings depend on how the compressor controls respond to a lower set point. Load/unload, modulating and VSD control behave differently.
  • The real constraint is the user who needs the most pressure. If one machine needs more, a booster or a dedicated supply may cost less than holding the whole ring main high.
  • Reducing pressure drop across refrigerated dryers, filters and undersized pipework is often what makes a lower set point possible.

Savings are project-specific. We measure them against a baseline and verify them after implementation; we don’t promise a blanket percentage.

When to call for a measured audit

An air audit logs pressure at the compressor and at your critical users across real production, so the new set point comes from data rather than a guess. It also measures leakage, which falls as pressure falls; a leak detection survey can then remove most of the reason the pressure was raised. If the distribution system is the bottleneck, our design and engineering team can size the fix.

Related: what is a compressed air audit, the hidden cost of compressed air leaks, and the energy optimisation solution. Estimate leak losses with the leak cost calculator.

FAQ

Questions engineers ask us

Where does the 1 % per 2 psi figure come from?

From the US DOE / Compressed Air Challenge sourcebook Improving Compressed Air System Performance, which gives it as a rule of thumb for systems in the 100 psig range: every 2 psi increase in discharge pressure raises energy consumption by approximately 1 % at full output flow. It asks you to check performance curves for centrifugal and two-stage, lubricant-injected rotary screw compressors.

What is 2 psi in bar?

About 0.14 bar. So the rule works out at roughly 1 % for every 0.14 bar, or about 7 % per bar, around 7 bar g. The calculator does the conversion for you.

What does the unregulated demand option do?

Leaks, open blowing and users without regulators consume more air at higher pressure. The sourcebook adds about 0.6–1.0 % per 2 psi where 30–50 % of demand is unregulated. We scale that in a straight line with the share you enter, up to 50 %.

How far can we lower our pressure?

Only as far as your most demanding user still gets the pressure it needs, after the pressure drop through dryers, filters and pipework. Measuring pressure at the compressor and at critical users is how you find the real margin.

Will lowering pressure always save energy?

Only if the compressor and its controls respond. Some control modes save less at reduced pressure than others, which is why the rule of thumb is indicative. A measured audit gives you the real figure.

Next step

Want measured numbers instead of estimates?

We log your compressors and demand, then rank the actions by verified kWh.

Start typing to search