AirMax commercial dehumidifiers
Fixed refrigerant dehumidifiers that hold a humidity target in stores, workrooms and production areas day and night.
Products · AirMax
An industrial dehumidifier in Cambodia has to remove a heavy, constant moisture load, so it must be sized to the room, the processes in it and the humidity you need to hold. Nexus Turnkey supplies the AirMax range as technology partner and authorised distributor: portable, commercial, ducted, ceiling-mounted, swimming pool, desiccant rotor and low-temperature units. We calculate the moisture load, choose refrigerant or desiccant technology for the target condition, then install, commission and maintain the system.
How to choose
| Your space and target | Usual technology | Why | Watch for |
|---|---|---|---|
| Warm room, moderate humidity target (warehouse, garment store) | Refrigerant: commercial, ducted or ceiling-mounted | Efficient when the air is warm and humid | Door openings and infiltration drive the real load |
| Low humidity target, or air that must be very dry | Desiccant rotor | Keeps removing moisture where refrigerant coils cannot | Regeneration heat is part of the running cost |
| Cool or cold room (cold stores, chilled production) | Low-temperature or desiccant units | Standard refrigerant coils ice up in cold air | Defrost strategy and drain routing |
| Temporary problem, construction drying, or a trial | Portable units | Fast to deploy and move | Condensate removal and electrical supply |
| Indoor pool hall | Swimming pool dehumidifier | Built for warm, chlorinated, very humid air | Corrosion protection and ductwork |
Families
Fixed refrigerant dehumidifiers that hold a humidity target in stores, workrooms and production areas day and night.
Desiccant rotor dehumidifiers for low humidity targets and cool spaces, where refrigerant coils stop working well.
Mobile dehumidifiers for local damp problems, temporary drying and trials before a permanent system.
Ducted dehumidifiers that distribute dry air evenly through large or divided spaces, with the unit out of the working area.
Dehumidifiers hung from the ceiling or installed in a void, keeping floor space clear for work, racking and cleaning.
Dehumidifiers built for warm, chlorinated pool-hall air, protecting the building fabric and the comfort of swimmers.
Dehumidifiers designed to keep working in cool and cold rooms, where standard units ice up and stop removing water.
Ranges are indicative. Confirm against the current manufacturer datasheet.
In a tropical climate, moisture arrives in a building all day and all year. It comes in with outside air, through doors and gaps, from people, from wet processes and from the products themselves. If the humidity in a room matters, for stored garments and fabric, packaged food, medicines, electronics or paper, then the relative humidity has to be held by equipment sized to that moisture load.
Nexus Turnkey is technology partner and authorised distributor for AirMax, and supplies the AirMax dehumidifier range:
There are two ways to take water out of air. A refrigerant dehumidifier cools air over a coil below its dew point, so water condenses and drains away, then reheats the air. It is efficient when the air is warm and humid. A desiccant dehumidifier passes air through a slowly turning rotor that adsorbs water vapour; a separate heated air stream regenerates the rotor and carries the water outside. It keeps working at low temperatures and low humidity targets where a cold coil would freeze or stop condensing.
Once the technology is right, capacity follows from the moisture load and the target. We estimate infiltration, door openings, ventilation air, occupants and process moisture, then select units and air distribution so the whole space reaches the target, not just the corner nearest the unit. The industrial dehumidification guide explains the method in more depth.
The outside air is the dominant moisture source for most of the year, and the monsoon season makes it worse. Three design points follow from that:
Our article on dehumidifiers for garment factories and warehouses covers the two most common cases we see, and humidity control in pharmaceutical and food plants covers stricter targets.
We survey the space, calculate the load, and propose the AirMax units, ductwork and controls to hold the target. We install and commission the system, verify humidity across the space at handover, and support it with filters, spare parts and planned maintenance. Where humidity and temperature both matter, we design it together with the HVAC and cooling system.
FAQ
Air conditioning is sized mainly to remove heat, not water. In humid weather it can bring a room to temperature while relative humidity stays high, especially at part load. Where humidity is the requirement, a dehumidifier sized to the moisture load does the job directly and lets the cooling system do its own.
Refrigerant units are usually the efficient choice in warm rooms with a moderate humidity target. Desiccant rotor units are the choice for low humidity targets, low temperatures, or where the air must be very dry, because they keep working where a cold coil cannot.
From the moisture load: outside air and infiltration, door openings, people, wet processes and products that release moisture, against the humidity you need to hold. We survey the space and log temperature and humidity where it helps, rather than sizing by floor area alone.
Yes. Many goods are damaged by sustained high humidity rather than by water: mould on textiles and paper, corrosion on metal parts, caking in powders. Holding the store below the humidity your goods tolerate prevents that. We help you set the target with your quality team.
Filter cleaning or replacement, coil and drain inspection, and for desiccant units, checks on the rotor, seals and regeneration heater. We include them in planned maintenance alongside your other air systems.
Next step
Send the room size, what is stored or produced there and the humidity you need to hold. We will come back with a load estimate and a technology direction.