Compressing air concentrates the water vapour it contains. When the air cools in the aftercooler, receiver, dryer and pipework, that vapour condenses into liquid condensate, carrying oil from oil-injected machines and particles from the intake.
In humid climates the volumes are large. As a worked physics example: a compressor delivering 10 m³/min of free air drawn in at 30 °C and 80% RH, compressed to about 7 bar(g) and dried to a +3 °C pressure dew point, releases roughly 14 litres of water an hour, about 340 litres a day.
Practical note: every point where condensate collects needs a reliable drain, ideally a zero-loss drain. Condensate from oil-injected compressors must pass through an oil-water separator before discharge, in line with local environmental requirements.