Gas volume changes with temperature and pressure, so a “cubic metre” means little without conditions. A normal cubic metre converts the volume to reference conditions. The most common definition is 0 °C and 1.01325 bar(a), as in DIN 1343, but other documents use 15 °C or 20 °C, and humidity assumptions vary.
Nm³ is widely used for nitrogen generators, gas consumption and specific energy. It lets you compare a generator’s output, or a plant’s air use, on a mass-equivalent basis.
Practical note: always state the reference conditions next to the number. Compressor FAD is normally expressed at inlet conditions, not normal conditions, so a compressor’s m³/min and a generator’s Nm³/h are not directly interchangeable. Convert before comparing, especially in hot climates where the difference is larger.