A PM-VSD compressor combines a variable speed drive with a permanent-magnet synchronous motor. Magnets in the rotor replace the induced rotor current of a conventional induction motor, which removes rotor losses and helps the motor hold its efficiency at low speed.
The benefit shows up at part load, which is where most plants run most of the time. Many designs also couple the motor directly to the airend, removing belts or gearboxes and their losses.
Practical note: compare PM-VSD and induction VSD machines on measured specific power across the speed range, not on motor type alone. Permanent-magnet motors need the matching drive and trained service; confirm local support for drive parts before you buy.