Specific power

The electrical power a compressor package draws per unit of free air delivered, usually stated in kW per m³/min or kW per 100 cfm at a stated pressure.

Specific power divides total package input power by free air delivery. It is quoted in kW per m³/min or kW per 100 cfm, always at a stated discharge pressure. Lower is better.

It is the fairest way to compare two compressors of different sizes or technologies, because it puts energy and output on the same scale. Over a machine’s life, electricity usually costs far more than the purchase price, so a small difference in specific power compounds every operating hour.

Practical note: compare figures only at the same pressure and on the same basis (full package, not bare motor). A datasheet value is measured at full load. At part load a fixed-speed machine’s real specific power rises because of unloaded running. The plant-level figure that captures this is kWh/m³, measured over time.

Next step

Need this applied to your plant?