Spec summary

At a glance

TypeTVOC adsorption: filtration units and adsorption towers
Flow / capacity (FAD)Towers: typically ≈2,000–20,000 CMH per unit; depends on the application
EfficiencyTypically ≈90–95 % VOC removal; depends on the compounds, concentration and carbon condition

Indicative. Confirm against the current manufacturer datasheet.

Key features

  • Activated-carbon filtration units for smaller airflows
  • Adsorption towers for larger exhaust volumes
  • Pre-filtration to protect the carbon from dust and mist
  • Access for carbon change-out
  • Simple operation with few moving parts besides the fan
  • Can follow a scrubber or precede the stack as a polishing stage

Applications

  • Printing and coating exhaust with low VOC concentrations
  • Small paint lines and spray booths
  • Laboratory and process fume extraction
  • Odour control at wastewater and food plants

The simplest way to remove VOCs at low concentration

Activated carbon has an enormous internal surface area, and many organic compounds stick to it as air passes through. For exhausts that carry volatile organic compounds (TVOC) at low concentrations, an activated-carbon system is often the simplest treatment: a fan, a pre-filter, a bed of carbon and a stack. AirMax supplies two forms:

  • Activated-carbon filtration units for smaller airflows, such as a single process or booth.
  • Activated-carbon adsorption towers for larger exhaust volumes. Typical tower capacities run from about 2,000 to 20,000 CMH per unit, depending on the application.

Typical VOC removal is in the region of 90 to 95 %. Actual performance depends on the compounds, their concentration, humidity, contact time and the state of the carbon. We state expected performance for your exhaust after we have characterised it.

How it works

Exhaust air passes first through a pre-filter that removes dust, paint overspray and mist, which would otherwise coat the carbon. It then flows slowly through one or more carbon beds. VOC molecules adsorb onto the carbon surface and clean air leaves through the stack. As the carbon fills, its capacity falls until compounds begin to pass through. At that point the carbon is replaced or regenerated.

Where it fits

  • Printing, laminating and coating exhaust at low concentration.
  • Small paint lines and spray booths.
  • Laboratory and process fume extraction.
  • Odour control, alone or after a scrubber.

For large, dilute airflows, a zeolite rotor concentrator is often more economical. For high concentrations, look at an RTO.

Selection notes

  • Carbon consumption is the running cost. It rises with solvent load. We estimate carbon life from your solvent use and the airflow.
  • Humidity matters. Water vapour competes with VOCs for space on the carbon. Humid exhaust, common in Cambodia, can reduce capacity, so some exhausts need conditioning first.
  • Temperature. Hot exhaust reduces adsorption. Cooling may be needed upstream.
  • Safety. Some compounds release heat as they adsorb. Design and monitoring account for it.

What Nexus provides

Exhaust characterisation, system design with ducting, fan and pre-filtration, installation and commissioning, and planned carbon change-out and maintenance. Carbon and pre-filter media are supplied through our spare parts service.

Next step

Request a quote for AirMax activated-carbon filtration units and adsorption towers

Send your operating data and we will size and propose the right configuration.