The first stage, and the one that protects the rest
Panel filters are flat filters in a frame. They are usually the first stage of filtration, taking out the coarse dust, lint, insects and grease that would otherwise load the finer and more expensive filters behind them, foul coils and wear fans. Specialised panels also handle odours and hot air. AirMax supplies:
- Pre-filter panels: disposable pleated or flat panels for coarse dust, in G2–G4 classes under EN 779.
- Washable aluminium panels: layered aluminium mesh that catches grease and heavy dust and can be cleaned and reused.
- Nylon mesh and metal mesh panels: coarse, reusable panels for lint, insects and large particles.
- Activated-carbon panels: for odours and some gaseous contaminants in recirculated or supply air.
- High-temperature panels: for ovens, dryers and hot process air, rated to about 250 °C. Confirm the rating for your duty on the datasheet.
Sizes and grades are selected to your housings and airflow.
How to choose
Start with what the filter has to stop and where it sits. Coarse dust in an AHU intake needs a disposable pre-filter. Grease in a kitchen or process extract needs a washable metal panel that can be cleaned. Lint in a garment plant may suit a mesh panel cleaned on a routine. Odour in recirculated air needs carbon. Hot air needs a panel and gasket rated for the temperature.
EN 779 has been superseded by ISO 16890, where coarse filters are rated as ISO Coarse. There is no exact one-to-one conversion, so we advise the equivalent for each application.
Where it fits
- AHU and ventilation pre-filtration.
- Kitchen and process extract.
- Air intakes for compressor rooms and equipment rooms, where dust is a problem.
- Recirculated air in offices and control rooms.
- Ovens, dryers and hot process air.
Selection notes
- Fit and seal. A panel that does not seal in its frame lets dust bypass. Measure housings, not old filters.
- Washable means washed. Reusable panels only work if they are cleaned and dried properly before refitting.
- Dust load. Sites near roads, construction, cement or agricultural processing load pre-filters quickly. Change on pressure drop or inspection.
- Carbon life. Carbon panels saturate. Replace them when odour breaks through or on the interval the datasheet recommends.
What Nexus provides
As technology partner and authorised distributor for AirMax, we match panels to your housings, advise grades and ISO 16890 equivalents, supply on a planned schedule and can change them under a maintenance contract.