Simple, compact nitrogen for moderate purity
A membrane nitrogen generator separates nitrogen from compressed air by passing it through bundles of hollow polymer fibres. It has few moving parts, delivers continuously and fits in a small space. The Nexus range membrane generators suit steady duties where the required purity is moderate.
Capacities are selected to your load. Ask for a datasheet.
How it works
Clean, dry compressed air flows through the bores of thousands of hollow fibres. Oxygen, water vapour and carbon dioxide permeate through the fibre walls faster than nitrogen and are vented. The gas that reaches the far end of the fibres is nitrogen-rich. Slowing the flow through the membrane raises purity; increasing it raises output at lower purity. There is no switching between vessels, so delivery is smooth and continuous.
Membrane performance depends on feed-air temperature and pressure. Many systems include a heater or temperature control to hold the feed at the membrane’s design condition.
Where it fits
- Tyre inflation and fire prevention.
- Blanketing of tanks and vessels.
- Packaging and storage where purity requirements are moderate.
- Sites that value compact, simple equipment.
For higher purity, compare a PSA generator. PSA generally suits higher purity requirements; membrane suits compact, lower-purity duty.
Feed air decides performance
Membrane fibres are damaged by oil aerosols and liquid water, and the damage is gradual and permanent. Feed air must be filtered through coalescing and activated-carbon stages and kept dry. In hot, humid Cambodian plants we size the dryer and filters for real site conditions and check the feed temperature reaching the membrane, because a feed that runs hot or cold shifts both purity and output.
Selection notes
- Confirm the purity you need. Membrane output falls as purity rises. If your process needs high purity, PSA is likely the better fit.
- Check the feed temperature at the membrane through the year.
- Plan the vent. The oxygen-enriched permeate is vented and must go somewhere safe.
What Nexus provides
Sizing of the generator and its feed-air treatment as one system, installation, commissioning with purity and flow verification by calibrated analyser, and planned maintenance of filters, drains and analysers.