A refrigerated dryer cools compressed air in a heat exchanger, drains the condensed water, then usually rewarms the outgoing air with the incoming stream. A typical design target is a pressure dew point of about +3 °C, which corresponds to ISO 8573-1 water Class 4 (PDP at or below +3 °C).
For most general plant air — tools, actuation, blowing, packaging lines in conditioned areas — that is dry enough and far cheaper to run than adsorption drying. It cannot go below freezing, so it is not suitable where lower dew points are required.
Size it on real conditions, not nameplate. Rated capacity assumes reference inlet temperature, ambient and pressure; tropical ambient and hot inlet air reduce it, so apply the manufacturer’s correction factors. Watch the dryer’s pressure drop too, because every extra bar of ΔP is paid for at the compressor.