Phnom Penh, serving Cambodia and the region

Ingersoll RandCompressed air aftercooler and separator

Aftercoolers and moisture separators

Aftercoolers that cool hot discharge air so most of its water condenses, and separators that remove that water before the dryer.

Spec summary

At a glance

TypeCompressed air aftercooler and separator

Capacities selected to your load. Ask for a datasheet.

Key features

  • Air-cooled or water-cooled aftercooler designs
  • Cools compressor discharge air close to ambient or cooling-water temperature
  • Cyclonic or baffle moisture separator with drain
  • Reduces the water load on dryers and filters downstream
  • Lowers the air temperature entering the dryer

Applications

  • Compressors without an integrated aftercooler
  • Reciprocating and high-pressure compressors
  • Hot compressor rooms where the dryer inlet runs hot
  • Portable and temporary compressors feeding a plant network

Cool it first, and most of the water drops out

Air leaving a compressor’s final stage is hot. Hot air holds a lot of water vapour, and cooling it is the cheapest way to make most of that water condense. An aftercooler cools the discharge air close to ambient or cooling-water temperature. A moisture separator then removes the liquid that forms, and a drain discharges it.

Most packaged screw compressors include an aftercooler and often a separator. Standalone units are needed for compressors without them, for some high-pressure and reciprocating machines, and where a hot compressor room means the integrated aftercooler cannot cool the air enough. We supply them from the brands we represent. Ask us which series are currently supplied in Cambodia.

How it works

In an air-cooled aftercooler, compressed air passes through finned tubes while a fan blows ambient air across them. In a water-cooled aftercooler, cooling water flows through a shell-and-tube or plate exchanger. Either way, as the air cools below its dew point, water condenses. The separator spins the air or changes its direction sharply so the heavier droplets fall out, collect and drain.

Where it fits

  • After compressors that do not include an aftercooler.
  • Ahead of a dryer that receives air too hot for its rated inlet temperature.
  • On temporary and portable compressors feeding a plant network.

Selection notes

  • Approach temperature. An aftercooler cools air to a few degrees above its cooling medium. In a hot compressor room, an air-cooled unit cannot cool below the room temperature, which is why room ventilation matters to the whole treatment train.
  • Water-cooled options. Where cooling water is available at a lower temperature, a water-cooled aftercooler can deliver cooler air to the dryer. Water quality must be managed to prevent fouling.
  • Separation efficiency. A good separator removes most of the liquid formed. A poor one passes it on to the dryer.
  • Drainage. Separated water carries oil from oil-injected compressors. It goes to an oil-water separator, not straight to drain.

What Nexus provides

Thermal check of the existing train, aftercooler and separator selection, installation with condensate routing, and maintenance: cooler cleaning, drain checks and, on water-cooled units, fouling inspection.

Next step

Request a quote for Aftercoolers and moisture separators

Send your operating data and we will size and propose the right configuration.

Start typing to search