The pipe decides what pressure reaches the machine
The compressor sets the pressure in the compressor room. The distribution decides what arrives at the machines. Undersized pipes, long dead-end headers, sharp restrictions and corroded steel all lose pressure, and the usual response, raising the compressor setpoint, costs energy every hour. The US Department of Energy’s rule of thumb is roughly 1 % of compressor energy for every 2 psi of extra pressure in the typical 100 psig range. Higher pressure also makes every leak worse.
Nexus Turnkey designs and installs compressed air distribution as part of the system: headers, a ring main, drops to machines, isolation and the final connections.
How a good network is built
- Loop, don’t dead-end. In a ring main, air reaches each drop from two directions, so pressure drop at the far end is lower and sections can be isolated without stopping the rest.
- Size for flow and growth. Pipe sizes come from flow, length, fittings and the pressure drop you can accept, with room for planned expansion.
- Keep water out of drops. Take-offs leave from the top of the header. Headers slope towards drip legs with drains.
- Isolate sensibly. Valves at each section and each drop allow maintenance and future tie-ins without a plant shutdown.
- Choose the material for the duty. Aluminium, stainless or galvanised steel each have a place. Corrosion, cleanliness, installation speed and budget decide which.
Where it fits
- New plants and compressor rooms.
- Existing plants with low pressure at the far end, frequent leaks or corroded pipe.
- Expansions that need air in new buildings.
Selection notes
- Measure first. Pressure readings at the compressor and at the furthest users show how much the network loses.
- Fix restrictions before raising the setpoint. Undersized drops, quick couplings and long hoses are often the real restriction.
- Re-pipe a live plant in phases. We plan cut-overs for weekends or planned stops, with temporary connections where needed, so production keeps running.
- Leaks. A new network is the moment to fix the leak habit. Our leak cost calculator shows what leaks cost.
What Nexus provides
Survey and pressure-loss measurement, network design with isometrics, material selection, phased installation, pressure testing and leak checks at handover, and as-built drawings. Savings are project-specific. We measure them against a baseline and verify them after implementation; we don’t promise a blanket percentage.