A contract worth signing is specific
A good compressor maintenance contract, or AMC, states exactly what is covered, when it is serviced, which parts are used, how fast someone responds and what you receive in writing after each visit. It covers the whole air system, not only the compressor: dryers, filters, drains, receivers and the oil-water separator. It schedules work by running hours. And it reports measured values, so you can see whether the system is holding its performance or drifting.
If a proposed contract cannot answer those points in a page, it is not ready to sign. This article sets out what to look for, three levels of cover and the clauses that matter. It belongs to our industrial compressed air guide.
Seven things every AMC should define
- Scope by asset. A list of every machine covered, with model and serial number: compressors, refrigerated or desiccant dryers, line filters, drains, receivers and separators. Anything not on the list is not covered.
- Service intervals in running hours. Manufacturers set intervals in hours. A contract based only on the calendar either over-services a lightly used machine or under-services a busy one.
- Parts and consumables policy. Genuine or approved parts, lubricants to the manufacturer’s specification, and who holds stock. Separators and oil filters that don’t meet the manufacturer’s specification can cause oil carryover and premature wear.
- Response time. How quickly someone answers, and how quickly an engineer arrives on site for a breakdown, by priority level.
- Reporting. Measured readings at every visit, recommendations and a record of parts changed.
- Exclusions. Damage from misuse, power faults, external causes or unauthorised modification, and how those are handled.
- Escalation and review. Who to call when something goes wrong, and a periodic review of the system’s condition and performance.
Ask, too, how the contract treats new equipment still under warranty. Manufacturer warranties usually depend on servicing at the stated intervals with approved parts and lubricants. A contract that ignores those conditions can leave you paying for a repair the warranty should have covered.
Three levels of cover
Plants need different depths of support. We structure maintenance contracts in three tiers. The details are always agreed per site.
| Essential | Performance | Total Care | |
|---|---|---|---|
| Planned servicing to manufacturer intervals | Yes | Yes | Yes |
| Scope | Compressors | Compressors and treatment | Whole air system |
| Measured reporting each visit | Core readings | Full readings, trend comparison | Full readings, trend and energy review |
| Leak and pressure checks | On request | Periodic | Built in |
| Parts and consumables | Quoted separately | Service kits included | Agreed parts cover included |
| Breakdown response | Standard | Priority | Highest priority |
Essential suits a plant with capable in-house staff that wants scheduled servicing done properly with genuine parts. Performance adds the treatment train and trend reporting, so you see problems such as a rising pressure dew point before they reach production. Total Care treats the air system as a single responsibility, with energy and leak review built in. Full detail is on our maintenance contracts page.
A service report full of ticks tells you the engineer visited. A report full of readings tells you how your air system is doing.
What a useful service report contains
Ask to see a sample report before you sign. It should include, for each machine:
- Running and loaded hours since the last visit.
- Discharge pressure and set-points.
- Discharge and oil temperatures against ambient.
- Differential pressure across separators and filters.
- Pressure dew point after the dryer.
- Drain function and the state of the condensate system.
- Alarms and trips since the last visit.
- Parts replaced and the next service due.
- Recommendations, ranked by urgency.
Where the plant has metering or a SCADA overlay, the report should also include kWh and delivered air, giving specific power in kW per m³/min. That single number shows whether the system is drifting in efficiency between visits.
Hot, dusty and humid: why intervals sometimes shorten
Manufacturer intervals assume reasonable conditions. Many Cambodian plants are not reasonable conditions.
- Dust loads intake filters and coats coolers, raising operating temperatures. Garment lint and cement dust are especially demanding.
- High ambient temperature pushes oil and discharge temperatures up. A fouled cooler in a hot room is a classic cause of high-temperature trips, and the hottest months before the monsoon expose it.
- Humidity produces large volumes of condensate. Drains that stick or block pass water downstream, so drain checks matter more here than in a dry climate. Zero-loss drains remove condensate without wasting air.
- Power quality issues can trip compressors and stress motors and drives. Note trips and their causes in the report.
A good contract adjusts inspection frequency for these conditions without inflating the full service schedule.
Red flags in a maintenance proposal
Some proposals look complete until you read them closely. Be cautious when you see:
- No asset list, or a list that does not match the machines on your floor.
- Fixed calendar visits with no reference to running hours.
- “Parts as required” with no statement of what is included, what is chargeable and whether parts are genuine.
- Response times without numbers. “Prompt” and “as soon as possible” are not commitments.
- No sample report, or a sample that is a checklist of ticks.
- The compressor in scope but the dryer, filters and drains out, without anyone saying so.
What the plant should provide
A contract works both ways. The service provider can only deliver what was agreed if the plant does its part:
- Safe access to every machine and a clear isolation procedure.
- A daily or weekly operator log of pressures, temperatures and alarms, so faults that develop between visits are visible.
- Prompt reporting of trips, leaks or unusual noise, rather than waiting for the next scheduled visit.
- Agreement on maintenance windows, so planned work does not collide with production peaks.
- A named contact who can approve recommended work.
When both sides keep to the agreement, maintenance becomes predictable. Breakdowns become the exception rather than the routine.
Clauses to read twice
- The asset list matches what is actually installed, with serial numbers
- Intervals are in running hours and follow the manufacturer's schedule
- Parts are genuine or approved, and lubricant meets the manufacturer's specification
- Response times are stated in hours, by priority, not as 'prompt'
- A sample service report shows measured readings, not just ticks
- Dryers, filters, drains and the oil-water separator are in scope or explicitly excluded
- Warranty conditions on new equipment are respected by the service schedule
- There is a named contact and an escalation route
Contracts and energy
A well-run AMC protects reliability first. It can also hold efficiency, because clean coolers, correct pressures and working drains keep the compressor where it was commissioned. If energy reduction is a goal, start with a baseline, which a compressed air audit provides. Savings are project-specific. We measure them against a baseline and verify them after implementation; we don’t promise a blanket percentage.
Choose the tier, then check the details
Start with the tier that matches your in-house capability and the cost of downtime to your plant. Then hold any contract, ours included, against the checklist above. We maintain Ingersoll Rand and Sollant compressors and the treatment equipment around them, with genuine parts from our spare parts service and stock on our spare parts products page.